Page 1: ...INSTALLATION INSTRUCTIONS AND OPERATING MANUAL WOOD STOVE Sense 100 Sense 103 Sense 200 Sense 203 Sense 03 27151 000 07 2014...
Page 2: ...11 Installing and connecting 11 Use 12 First use 12 Fuel 12 Lighting 12 Burning wood 13 Controlling combustion air 14 Extinguishing the fire 15 Removing ash 15 Fog and mist 15 Resolving problems 15 M...
Page 3: ...ied please always use original parts The appliance is intended for use in a living room It must be hermetically connected to a properly work ing flue We advise you have the appliance installed by an a...
Page 4: ...ress of the producer as pre scribed in article 11 subsection 5 Dovre N V Nijverheidsstraat 18 2381 Weelde Belgium 5 If applicable name and contact address for the authorised whose mandate covers the t...
Page 5: ...istance weight carry of chimney Not determined Nominal output 4 9 kW Efficiency 79 5 10 The performance of the product described in points 1 and 2 conform with the performance reported in point 9 This...
Page 6: ...air inlets and alert the fire service If the glass in the appliance is broken or cracked it must be replaced before you can use the appliance again Ensure that there is adequate ventilation in the ro...
Page 7: ...nd in a zone that is not affected by surrounding buildings trees or other obstacles The flue outside the house must be insulated The flue should be at least 4 metres high As a rule of thumb 60 cm abov...
Page 8: ...d between the connecting tube and combustible material The rule of thumb for a single walled tube is a distance of 3x the diameter If a lining shell is fitted around the tube a distance of 1x the dia...
Page 9: ...installation It is easier to move the appliance and to avoid damage if the removable parts have been removed Note the location of the removable parts so that you can re position the parts in the corre...
Page 10: ...e By using this heat shield you can reduce the distance to the combustible material See appendix Distance from combustible material For a rear connection the escape plate needs to be removed You can d...
Page 11: ...ring the outside air connection If the appliance is installed in a room with insufficient ventilation you can install the outside air connecting kit to the appliance The air supply tube is 100 mm in d...
Page 12: ...e of wood burns slowly with calm flames Softwood contains more resins burns faster and sparks more Use seasoned wood that contains no more than 20 moisture The wood should have been seasoned for at le...
Page 13: ...open B o o Secondary air open glass wash o Air for post combustion open A o Air for post combustion open never close entirely for proper combustion Burning wood After you have followed the instructio...
Page 14: ...air slide is completely closed a small air vent remains open to allow for the post combustion under the baffle plate 09 20021 019 1 2 3 The primary air inlet regulates the air under the grate 1 The se...
Page 15: ...as died completely Removing ash After wood has been burnt a relatively small amount of ash is left over This ash bed is a good insulating layer for the stove base plate and improves com bustion It is...
Page 16: ...ay develop hairline cracks but this does not affect their performance adversely Cast iron inner plates last a long time if you remove frequently the ash that can accumulate behind them If accumulated...
Page 17: ...ur This is a normal phenomenon and has no impact on the functioning of the stove Ensure that the stove is not overburdened If it does become overburdened then the surface gets very hot possibly result...
Page 18: ...04 05 06 07 08 09 10 11 12 Pos Part nr Description Quantity 01 03 66544 002 base plate 1 02 03 77429 002 fire basket right rear 1 03 03 77428 000 fire basket left rear 1 04 03 77425 002 fire basket r...
Page 19: ...ses 4 5 g s Flue gas temperature measured in the measurement section 247 C Temperature measured at appliance exit 317 C Minimum draught 15 Pa CO emission 13 O2 0 18 NOx emission 13 O2 81 mg Nm CnHm em...
Page 20: ...Appendix 2 Dimensions Sense 100 09 20021 001 470 9 0 0 2 8 5 360 3 0 0 7 9 0 1 5 0 1 0 0 150 1 0 0 3 7 5 20 Subject to change because of technical improvements...
Page 21: ...Sense 103 09 20021 002 470 9 0 0 2 8 5 360 3 0 0 7 9 0 1 5 0 1 0 0 150 1 0 0 3 7 5 Subject to change because of technical improvements 21...
Page 22: ...Sense 200 09 20021 003 470 9 8 0 3 6 5 360 1 5 0 3 8 0 8 7 0 1 0 0 150 1 0 0 3 7 5 22 Subject to change because of technical improvements...
Page 23: ...Sense 203 09 20021 004 470 9 8 0 3 6 5 360 1 5 0 3 8 0 8 7 0 1 0 0 150 1 0 0 3 7 5 Subject to change because of technical improvements 23...
Page 24: ...ombustible material thickness 100 mm Please note In order to guarantee the supply of combustion air when there is no outside air supply con nection the distance from the connection collar for the outs...
Page 25: ...ness 100 mm Please note In order to guarantee the supply of combustion air when there is no outside air supply con nection the distance from the connection collar for the outside air to the wall must...
Page 26: ...of fireproof floor plate 09 20021 030 B B A Minimum dimensions of fireproof floor plate A mm B mm Din 18891 500 300 Germany 500 300 Finland 400 100 Norway 300 5 26 Subject to change because of techni...
Page 27: ...t deposit hermetically tight no chinks Chimney stack incorrect Sufficiently high above the roof no obstacles in the vicinity Air inlets set incorrectly Open the air inlets completely Appliance connect...
Page 28: ...ensions 20 Connecting outside air supply 11 Connection collar for connection to chimney 10 11 Connection to chimney at the rear 11 at the top 10 rear 11 top 10 Controlling air supply 15 Creosote 14 D...
Page 29: ...cked 17 deposit 27 replacing 17 Glass damaged 17 H Heat shield 10 Heat insufficient 15 27 Hinge adjust 17 I Inner plate vermiculite 9 Inner plates fire resistant remove 9 Installing dimensions 20 K Ki...
Page 30: ...th fuel 15 U Unsuitable fuel 12 V Vermiculite fire resistant 9 Vermiculite inner plates 9 W Walls fire safety 8 Warning chimney fire 12 14 chimney fires 6 fireproof inner plates 12 flammable materials...