Appendix 1: Technical data
Model
BOLD 300/400
Nominal output
7 kW
Flue connection (diameter)
150 mm
Weight
130 kg - 145 kg
Recommended fuel
Wood
Fuel property, max. length
35 cm
Mass flow of flue gasses
5.6 g/s
Flue gas temperature measured in the measurement section
246 °C
Temperature measured at appliance exit
356 °C
Minimum draught
12 Pa
CO emission (13%O
2
)
0.10 %
NOx emission (13% O
2
)
90 mg/Nm³
CnHm emission (13%O
2
)
102 mg/Nm³
Particulate emission
22 mg/Nm³
Particulate emission in accordance with NS3058-NS3059
2.64 g/kg
Efficiency
80 %