Appendix 1: Technical Data
Model
25 heat exchanger
Nominal output
10.8 kW (4.4 kW water side)
Max. operating pressure
3 bar
Max. input temperature
100°C
Flue side pressure loss
<2 Pa
Supply/return connection
G 3/4 - ISO 228
Connection to pressure relief safety mechanism
R 1/2 - EN 10226
Thermal safety valve sensor connection
Rp 1/2 - EN 10226
Thermal protection water connection
2 x Ø 15 mm
Drain connection
Rp 1/2 - EN 10226
Fuel
Wood, maximum 50 cm
Flue gas mass flow
10.1 g/s
Flue gas connection
Ø 150 mm
Flue gas temperature measured in the measurement
section
143.5°C
Flue gas temperature measured directly after the appli-
ance connection
340 °C
Minimum draught
12 Pa
CO emission (13%O
2
)
0.099%
Nox emission (13%O
2
)
54 mg/Nm³
CnHm emission (13%O
2
)
38 mg/Nm³
Particulate emission
40 mg/Nm³
Efficiency
84%
Appliance weight
150 kg
Heat exchanger weight
61 kg
Weight of water
24 kg (24 L)
Weight of insulating cover
35 kg
Weight of insulation (Rockwool HT600)
10 kg
Total weight
280 kg
Subject to change because of technical improvements
13
Summary of Contents for 2575 CBS WW