1.3 - I
NSTALLATION
INFO
Installation Guide DeltaWave
C
HAPTER
1
9
1.3.9 E
XHAUST
SYSTEM
Two exhaust gauges of 160 mm (6.3”) are provided. One for the flux unit and one for the solder
fumes. These should be connected with the customer’s exhaust system (not supplied by
Vitronics Soltec).
For specifications see Chapter Appendix in this manual.
•
Inflammable and/or explosive gas might develop in the machine because of the evaporation
of the solvent in the flux.
•
An exhaust system that functions well, will solve most of this problem.
•
It is therefore necessary to have a sufficient exhaust in the machine.
•
The exhaust system also has to be checked continuously on its functioning well.
•
The machine is prepared to interfere in the E-stop circuit of the machine with a potential
free contact of the exhaust system. This contact has to be normally open, and therefore
closed when the exhaust functions well (fail safe).
NEVER USE THE MACHINE WITHOUT THE EXHAUST SYSTEM
1.3.10 P
ERSONAL
COMPUTER
The complete Personal Computer is packed in boxes for transporting. Unpack all boxes and put
the PC, monitor and keyboard on the PC-arm. Connect all cables.
1.3.11 F
ILLING
THE
SOLDERPOT
There are two different ways to fill the solderpot:
1.
Filling with granulated solder.
When granulated solder is used: fill solderpot equally.
The level of the solder in the bath shouldn’t be less than 15 mm and not more than 20 mm below
the top off the solderpot (solderpumps not running).