PAGE 6
338 REV.990801
OVERHUNG LOAD RATING
PG-50-OH
T
y
L
L =
c x SF
(y + a) AF
Allowable thrust or tension load in lbs. = T x SF
= lbs
The magnitude and location of a load is dependent on the following factors:
SF = service factor (Table A)
AF = application factor (Table B)
a = bearing geometry constant = -3.10
T = basic thrust or tension load = 25,300
c = basic load constant = 51,000
L = allowable overhung load in lbs.
y = distance of load centre to mounting face in inches
up to full load occasionally
Intermittent duty at variable loads,
3 hr. day, intermittent duty, full load
8 hr. day, continuous duty, full load
24 hr. day, continuous duty, full load
0.75
1.00
1.50
2.68
1.00
1.25
1.50
2.50
Chain drive
Gear
V-belt
Flat belt
TABLE A