background image

T196SV-CV Crude Vapor Recovery Vent 

Instruction & Maintenance Manual

Product Description 

Civacon’s T196SV-CV Crude Oil Vent is manufactured to withstand high pressure 
crude applications.  It will open against 35 psi tank pressure.  The unique 
patent pending dual stage poppet will relieve tank pressure during the 1

st

 stage, 

allowing for optimal venting during the 2

nd

 stage action.  It is designed and 

tested to take the punishment of crude oil transportation at temperatures from 
-40

o

F to 220

o

F (-40

o

C to 104

o

C).  A new cap design threads into the top of the 

vent which allows for a better seal and eliminates the snap ring on top.

WARRANTY 

All parts and products are thoroughly inspected and tested from the time raw 
material is received at our plant, until the product is completed. We guarantee 
that all products are free from defects in materials and workmanship for a 
period of one year from the date of shipment. Any product that may prove 
defective within said one year period will, at our discretion, be promptly 
repaired, replaced or credit given for future orders. This warranty shall not apply 
to any products which has been altered in any way, which has been repaired by 
any party other than an authorized service representative, or when such a failure 
is due to misuse or condition of use. We shall have no liability for labor costs, 
freight costs or any other costs or charges in excess of the amount of invoice  
for the products. 

THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR 
IMPLIED AND SPECIFICALLY THE WARRANTIES OF MERCHANTABILITY  
AND FITNESS FOR A PARTICULAR PURPOSE. 

WARNING!!  

 

CIVACON

 products should be used in compliance with the applicable federal, 

state and local laws and regulations. Product selection should be based on 
physical specifications and limitations, compatibility with the environment,  
and the material being handled. 

CIVACON MAKES NO WARRANTIES OF 
FITNESS FOR A PARTICULAR PURPOSE. 

TECHNICAL ASSISTANCE  

 

If at any time during the installation a question arises that is not covered in this 

manual or with any other applicable documents feel free to call the Customer 

Service Department or visit our website at 

www.civacon.com. 

In the U.S., call 1-888-526-5657  

In all other countries, call your local agent. 

Manual 

This manual contains the inspection, maintenance schedule and instructions 
for repairing and replacing parts for the T196SV-CV crude vapor recovery vent. 
The following schedule, based on the environmental conditions in the northern 
United States, is only a recommendation: Inspection and maintenance intervals 
must be adjusted according to use and operating conditions.  Compatible with 
diesel, bio-diesel, gasoline, ethanol and methanol

NOTE:

 All information subject to engineering and/or other changes. All trade names are copyrighted. Patents Pending. ©2018 Civacon. ©2018 Delaware Capital Formation, Inc.  

All Rights Reserved. DOVER and the DOVER logo are registered trademarks of Delaware Capital Formation, Inc., a wholly-owned subsidiary of Dover Corporation.

www.civacon.com

     

9393 Princeton-Glendale Road

     

Hamilton, Ohio, USA 45011

Phone: (800) 560-6601

12831PA

RevA  Apr2021

Reviews: