![Dover markem-imaje SmartDate 5 Maintenance Manual Download Page 183](http://html1.mh-extra.com/html/dover/markem-imaje-smartdate-5/markem-imaje-smartdate-5_maintenance-manual_2524945183.webp)
5-37
SmartDate 5 06/08
5.15
Communication Problems
5.15.1
Communications Do Not Work
If DCP communication fails between SmartDate 5 and CoLOS Control, check the
following:
Ethernet Communications
•
Is the correct IP address configured?
•
Is the correct IP Subnet mask configured?
•
Is the DCP Actor name (Device Network ID) on the SmartDate 5 the same as
Device Network ID on CoLOS Control?
•
Are the Ethernet cable or connectors faulty?
RS-485 Communications
•
Is the SmartDate 5 serial Port 1configured correctly? (DCP RS-485)
•
Is Serial Port 1 Baud Rate configured correctly? This must be the same as the
setting on CoLOS Control.
•
Is Serial Port 1 CimComms Node configured correctly? This must be the same
as the Device setting on CoLOS Control.
•
Is the DCP Actor name (Device Network ID) on the SmartDate 5 the same as
Device Network ID on CoLOS Control?
•
Is the correct communications cable connected between the SmartDate 5
Serial port and the CimLan Communications card?
Summary of Contents for markem-imaje SmartDate 5
Page 1: ... ...
Page 2: ......
Page 9: ...SmartDate 5 Maintenance Manual SECTION 1 GENERAL INFORMATION ...
Page 10: ......
Page 13: ...SmartDate 5 Maintenance Manual SECTION 2 SETUP AND TIMING ISSUES ...
Page 14: ......
Page 37: ...SmartDate 5 Maintenance Manual SECTION 3 MAINTENANCE ...
Page 38: ......
Page 77: ...SmartDate 5 Maintenance Manual SECTION 4 TECHNICAL INFORMATION ...
Page 78: ......
Page 145: ...SmartDate 5 Maintenance Manual SECTION 5 TROUBLESHOOTING ...
Page 146: ......
Page 189: ...SmartDate 5 Maintenance Manual SECTION 6 RECOMMENDED SPARES ...
Page 190: ......
Page 197: ......
Page 198: ...User Documentation Department ...