10.2 Connect XMT Exd probes

M2050 MagLink LX 4 Installation Manual | Dover Fueling Solutions

32

Summary of Contents for MagLink LX4

Page 1: ...ProGauge MagLink LX 4 Installation Manual Part Number M2050 Revision 4 MagLink LX 4 ...

Page 2: ...Connection to the Intrinsically Safe XMT SI and DMP SI Probes 19 7 2 Connection to the XMT Explosion proof Probe 20 7 3 Connection to the RF Receiver for XMT SI RF 21 7 4 Interface to Relay Diagram of Connectors 22 7 5 DIP Switch Configuration 24 7 6 Micro SD Card 25 7 7 Close and Start Up the Console 26 7 8 DB9 Connections to a Management System 26 7 8 1 FuelPOS DIALOG Fuel Management System 26 7...

Page 3: ...n 10 Wiring Diagrams 31 10 1 Connect XMT SI probes 31 10 2 Connect XMT Exd probes 32 10 3 Connect RF Probes 33 10 4 Connect On Off Sensors 34 Appendix A Console Dimensions 35 M2050 MagLink LX 4 Installation Manual Dover Fueling Solutions 3 ...

Page 4: ...nd or changes in the product and or associated programs Start Italiana S r l is not liable for damages of any kind including those resulting in the document including typographical errors Making copies citing quotes or other reproductions of all or part of this document is permitted only after written consent of Start Italiana S r l Patents protect trademark or name Copyright 2022 Start Italiana S...

Page 5: ...amage to persons and or property and or pets caused by the failure to obey safety instructions All approved personnel must know all safety requirements in this manual the configuration manual and the user manual Refer directly to an approved service provider or manufacturer for questions about the operation of the equipment IMPORTANT You must read and obey all safety instructions in this manual be...

Page 6: ...le in the field as shown in the M2052 MagLink LX 4 LX Plus User Manual WARNING This device must not be discarded with household waste This device is labeled in accordance with European Directive 2012 19 UE concerning used electrical and electronic appliances waste electrical and electronic equipment WEEE This guideline gives the methods for the return and recycling of used electronic devices as ap...

Page 7: ...tained in this manual refer to a specified selection by the user Refer to the M2051 MagLink LX 4 LX Plus Configuration Manual for more information on how to set units of measure M2050 MagLink LX 4 Installation Manual Dover Fueling Solutions 7 ...

Page 8: ...ult in death or serious injury CAUTION Indicates a possibly hazardous situation that if not prevented could result in minor or moderate injury NOTICE Indicates important information not related to hazards A condition that if not prevented can result in property damage SAFETY INSTRUCTIONS Indicates instructions and procedures related to safety or gives the location of safety equipment 3 2 Informati...

Page 9: ... that is recommended to make another step or procedure easier INFORMATION This panel shows references to more information in other sources READ CAREFULLY This panel points to information that must be fully read and understood before doing the procedure s that comes after M2050 MagLink LX 4 Installation Manual Dover Fueling Solutions 9 ...

Page 10: ...he table below shows the primary technical characteristics of the console Element Characteristic Display Display TFT 7 inch Dimensions 155 x 88 mm Console Dimensions Width 267 mm Height with cable 215 mm Depth 80 mm The illustration below shows the ports and connections on the bottom of the console Make sure that the power cable is correctly installed Put the Power Switch to the on I position to s...

Page 11: ...M2052 MagLink LX 4 LX Plus User Manual RJ45 For console configuration and local network connections Refer to the M2051 MagLink LX 4 LX Plus Configuration Manual RS232 Com 1 Serial port for connection to management systems FCC POS DCD RS232 Com 2 Serial port for connection to management systems FCC POS DCD Ground connection Ground connection of the internal Intrinsically Safe barrier Use a dedicate...

Page 12: ... symbol 0434B of 01 2004 according to ISO 7000 l Serial number l Year of production l Power Supply VAC and Hz l Power consumption VA l Operating temperature C l Ingress protection IP grade l Fuse rating l Indication that inside there is intrinsically safe circuit M2050 MagLink LX 4 Installation Manual Dover Fueling Solutions 12 ...

Page 13: ...acturer l Equipment Type BRA SI BRA SIP or BRA 2SIP l ATEX Reference number of the certificate l ATEX Marking Ex II 1 G Ex ia Ga IIB l Serial number l Electrical data M2050 MagLink LX 4 Installation Manual Dover Fueling Solutions 13 ...

Page 14: ...xplosion or fire can occur if damage is caused to the intrinsic safety of the device and high voltages are sent to the Hazardous Area 6 2 Installation Location Select a location for the console installation where weather cannot cause negative effects or damage to the electrical circuits high and low temperatures high humidity direct sunlight etc NOTICE Install the console in a place that is protec...

Page 15: ... The cable supplied with the console already complies with these regulations l Make sure the power plug is connected to the ground and protected against short circuits and power surges l Make sure to connect the I S ground to the site s earth system Use a dedicated 4 0 mm2 copper cable see the illustration below l The power cord must be easy to identify and must have easy access so it can be used ...

Page 16: ...over carefully and disconnect the ribbon cable from the rear panel of the console as shown in the illustration above Put the cover and screws in a temporary safe location where they can be found later and where the components cannot be damaged M2050 MagLink LX 4 Installation Manual Dover Fueling Solutions 16 ...

Page 17: ...re are four 4 mounting screw holes in the unit see the illustration above for the locations of the holes c Use a pen to identify the screw hole locations on the wall d Drill the holes at the screw hole location marks e Tap the holes for an applicable screw size or put screw anchors in the hole NOTE It is recommended to use size 6 Fischer wall anchors f Attach the unit to the wall with the applicab...

Page 18: ...nents of the rear of the console Component Description 1 Power Supply Unit PSU protection panel 2 BRA 2SIP barrier for connection to the DMP SI 485 and XMT SI 485 probes 8 8 3 Four 4 Built in Relays Six 6 Inputs M2050 MagLink LX 4 Installation Manual Dover Fueling Solutions 18 ...

Page 19: ...2 Blue RS485B Terminal 3 White 0 V Terminal 4 MR4 Safety Barrier Input up to eight 8 probes Red 12V Terminal 1 Brown RS485A Terminal 2 Blue RS485B Terminal 3 White 0 V Terminal 4 If a site installation has more than 16 probes tanks you must use an external MagDirect barrier connected to the console MR1 or CN7 see below terminal blocks Each MagDirect barrier can hold up to eight 8 probes See the Wi...

Page 20: ...es not go through the intrinsically safe barrier the barrier is not applicable in this installation The table that follows shows the wiring connections between the XMT Probes and the LX 4 Console main board CN7 terminal block Connection Specification CN7 White 0 V Terminal 4 Blue RS485B Terminal 3 Brown RS485A Terminal 2 Red 12V Terminal 1 M2050 MagLink LX 4 Installation Manual Dover Fueling Solut...

Page 21: ... barrier the barrier is not applicable in this installation The table that follows shows the wiring connections between the RF Receiver and the LX 4 Console main board CN7 terminal block Connection Specification CN7 White 0 V Terminal 4 Blue RS485B Terminal 3 Brown RS485A Terminal 2 Red 12V Terminal 1 Refer to the RF Receiver installation manual s section on electrical connections for the correct ...

Page 22: ... Relay Diagram of Connectors The illustration above shows the connections of a MagLink LX 4 Console The table that follows shows the console connections M2050 MagLink LX 4 Installation Manual Dover Fueling Solutions 22 ...

Page 23: ...age DEEP 3 OFF 1 GND activated with a positive voltage 2 Input 1 3 Input 2 4 Input 3 5 Input 4 6 Input 5 7 Input 6 CN11 Main Board Connector The table that follows identifies the Connectors and related status LEDs Connector Specification LED1 Power LED output to probe L1 Relay 2 status LED On relay energized L2 Relay 3 status LED On relay energized L3 Relay 4 status LED On relay energized L9 Input...

Page 24: ...tion of the DIP Switch block on the Main Board The table that follows shows the configurations of the DIP Switch Switch Number Description 1 Relay function Normal Closed Under Power OFF Normal ON Closed Under Power 2 OFF Internal inputs not available for alarms ON Internal inputs available for alarms 8 Enables Weights Measures lock W M OFF W M disabled ON W M enabled M2050 MagLink LX 4 Installatio...

Page 25: ...D Card contains the operating system firmware configuration and a history of the console IMPORTANT Do not remove the micro SD card while the console is in operation The console cannot function without the SD card in place M2050 MagLink LX 4 Installation Manual Dover Fueling Solutions 25 ...

Page 26: ...ector into an electrical wall outlet 4 Put the Power Switch into the ON position Continue with the configuration as shown in the Console Configuration Manual 7 8 DB9 Connections to a Management System The console can be connected through the RS232 port Com 1 Com 2 or through TCP IP on these management systems DIALOG ORPAK DOMS PIGNONE FUEL POS VR350 Interface Probe emulation GILBARCO VR350 interfa...

Page 27: ...3 PIN 5 PIN 5 Connect PIN 4 with PIN 6 7 8 2 GILBARCO Fuel Management System Console DB9 GILBARCO System RJ45 PIN 2 PIN 8 PIN 3 PIN 1 PIN 5 PIN 4 7 8 3 Wayne Fusion Fuel Management System M2050 MagLink LX 4 Installation Manual Dover Fueling Solutions 27 ...

Page 28: ...9 PIN 2 PIN 2 PIN 3 PIN 3 PIN 5 PIN 5 IMPORTANT Do not use cabling longer than 15 meters 3 2 feet for RS232 serial connections between the console and the management system M2050 MagLink LX 4 Installation Manual Dover Fueling Solutions 28 ...

Page 29: ...pproved and certified personnel refer to this installation manual NOTICE Changes to this console are not permitted unless they are approved by the manufacturer IMPORTANT Do regular inspections to make sure the console is clean and that the condition of the console and its connections operate satisfactorily Do not use compressed air or liquid detergents to clean the touchscreen or the console Clean...

Page 30: ... support can get access through a third party program such as TeamViewer If technical support cannot get access to the console in one of these two methods the user must supply technical support with the log files and the database backup of the console Refer to the Utility section of the M2051 LX 4 Configuration manual for for information on log files and the database backup in the console M2050 Ma...

Page 31: ...Section 10 Wiring Diagrams 10 1 Connect XMT SI probes M2050 MagLink LX 4 Installation Manual Dover Fueling Solutions 31 ...

Page 32: ...10 2 Connect XMT Exd probes M2050 MagLink LX 4 Installation Manual Dover Fueling Solutions 32 ...

Page 33: ...10 3 Connect RF Probes M2050 MagLink LX 4 Installation Manual Dover Fueling Solutions 33 ...

Page 34: ...10 4 Connect On Off Sensors M2050 MagLink LX 4 Installation Manual Dover Fueling Solutions 34 ...

Page 35: ...Appendix A Console Dimensions M2050 MagLink LX 4 Installation Manual Dover Fueling Solutions 35 ...

Page 36: ...d support Barrier label 2 1944 8 10 2021 Updated ATEX Label new Tech nical Support procedure 3 1998 3 14 2022 Add note for Maximum of probes 4 2045 7 28 2022 Add power shutdown instruc tion note warning panel Removed IFSF GSM card from inner com ponent list NOTE It is possible that older software versions might not support all features M2050 MagLink LX 4 Installation Manual Dover Fueling Solutions...