Document 41-1600     Revision: A 

Pg. 

1

 

Revision Date: 02/18/22 

Dover Motion DOF-5 Quick Start Guide for CAN Communication

 

This guide covers the basic steps for using a DOF-5 stage with Pro-Motion for basic control & 
testing. See the DOF-5 User Guide for more information. 

1)

 

The USB drive included with the stage has the following materials: 

a.

 

41-1602 (IXAAT Driver Installation File) 

b.

 

36105-01 (C-Motion Startup Guide & Examples)  

c.

 

41-1114.pdf (DOF-5 User Guide)

 

 

d.

 

41-1212.pdf (DOF-5 Software Guide) 

e.

 

41-1600.pdf (DOF-5 Quick Start Guide, CAN)  

f.

 

######_Config.txt (Configuration File) 

g.

 

FIR_SN_######.pdf (Final Inspection Report) 

 

  

2)

 

Remove the shipping stop (See image) 

3)

 

The User Guide (41-1114.pdf) and troubleshooting section 15) 
below have information on the DIP switches for communications 
setup.  

a.

 

The DOF-5 ships with these switches pre-set per the order, 
reference Final Inspection Report on USB drive for shipped 
configuration. 

 

4)

 

Mounting the stage for powerup 

Note that these are calibrated stages, orientation and load matter! 

a.

 

Attach the specified load to the stage (the objective, lens, etc.) or a dummy 
mass. 

Without the load stage will be unstable and/or buzz. 

b.

 

Ensure the correct orientation, counterbalance at the top (See image) when 
mounted vertically. Mount in a horizontal orientation if ordered without 
counterbalance.

 

 

 

5)

 

If using IXAAT CAN Adapter, install IXAAT Drivers included on  
USB (41-1602) 

6)

 

If using Dover Motion supplied cabling (36102-00), connect cable 
to stage and tighten retention screws. Connect cable to serial 
communications adapter. With power supply powered OFF, 
connect to 24V power supply. Turn power on. 

 

 

7)

 

Download and install the Pro-Motion user interface from the provided USB 

Install file is named: Pro-Motion5.20.exe.  Note: The DOF requires Pro-Motion version 5.20 to work properly        

 

8)

 

Start Pro-Motion, and the Select Interface Type box opens 
automatically 

a.

 

Select the 

“C

AN

 communications type for CAN 

Communication and the Port the DOF-5 is connected to (See 
Step 

Error! Reference source not found.

b.

 

 

c.

 

 

9)

 

Set the Stage Units 

a.

 

Click Units, select Linear units, change Count to Millimeters, 
and enter one of the following numbers depending on the 
resolution of the encoder you ordered.  The resolution is 
shown on page 1 of the FIR Test Report: 

 

i.

 

5nm resolution encoders: 200000 counts/mm 

ii.

 

1.25nm resolution encoders: 800000 counts/mm 

10)

 

Click “Drive Signal Scaling…” and change “Leg Currents” to 

“0.1611.” Then click “Apply” and “OK.” Click “OK” on the “Units” 

window to close it. 

 
 
 

 
 
 
 
 
 
 
 
 

 

Vertical 

Orientation 

 

Counterbalance at the 

Top 

 

Choose CAN 