Cooling
system not
operating
Coffee
vending
unit not
operating
3
Reference Card Error Types
contact the
service if
required
Message
Possible cause
Possible action
If it was
impossible to
remedy the fault:
Sensors in bucket or drip tray
are wet
Cup mechanism not
transporting cups
Door not fully closed
No power
Empty and dry sensors
Check cup mechanism
Refill cup magazine
Close and lock door
Check fuses/power cord
Canister empty
Canister not connected
Canister not correctly inserted
Ingredient sticking to auger
drive mechanism
Refill canister
Reinsert canister
Check label and reinstall
canister
Remove canister, clean auger
drive mechanism and reinstall
From outside remove dust
from venting grid at rear of
machine
Blockage in mixing funnel
Replace/clean blocked part/s
Check if they are positioned
correctly
Funnel/whipper housing/hoses
not correctly connected
Whipper seal leaking or not
installed
Reinstall and reconnect
components
Replace whipper seal
Water dripping from hot-water
hoses
Liquid has been poured into
machine
Water tank and valves must
be decalcified
contact the
service if
required
contact the
service if
required
Bucket/canister/whipper
housing/delivery hoses/drip
tray/trough not correctly
installed
Install components correctly
Check sensors, reposition
contact the
service if
required
No display
or machine
not
operating
No
ingredient
Mixing
system
overflows
Leak in
mixing
system
Bucket or
drip tray
filled with
water
Liquid
escaping
from
machine
Ingredient canisters/
BIB-packs are empty
Clean trough
contact the
service if
required
Machine
only
dispensing
water
Refill ingredients
Replace BIB-packs
contact the
service if
required
contact the
service if
required
Only
cooling
system
operating
contact the
service if
required
Quick Reference Guide
Cafitesse 3000
75409800
1
04.01