Summary of Contents for E8ANL-DIN

Page 1: ...t to analog interface Web Server Configuration Manual models E8ANL DIN E8ANL DIN JBOX E8ANL DIN JBOX PS Doug Fleenor Design Inc 396 Corbett Canyon Road Arroyo Grande CA 93420 805 481 9599 Voice and FA...

Page 2: ...set in order to access the web pages and configuration options The two methods for establishing this web connection are using Dynamic Host Configuration Protocol DHCP and Node Discovery or Static IP a...

Page 3: ...t www dfd com To do so navigate to the Node Discovery Page under the Ethernet Products heading Node Discovery is a simple application that allows you to find Doug Fleenor Design Ethernet devices on yo...

Page 4: ...e same as the IP listed on the E8ANL DIN 3 Open any web browser and type the IP Address listed on the unit into the address bar This opens the internal web server of the E8ANL DIN Additionally Node Di...

Page 5: ...of the current setup for the Ethernet to analog interface This includes its name description current version of firmware DHCP status IP Address Subnet Mask MAC Address sACN parameters and ArtNet para...

Page 6: ...e the E8ANL DIN s network settings From here you can enable and disable DHCP and change both the Static IP and Static Subnet Mask to best fit the needs for your system Please note that the Restart Int...

Page 7: ...NL DIN using the sACN lighting protocol From this page you can enable and disable sACN as well as configure its universe from 1 to 63 999 and its starting slot from 1 to 512 New settings are only appl...

Page 8: ...t lighting protocol From this page you can enable and disable ArtNet as well as configure its universe from 0 to 15 its subnet from 0 to 15 its net from 0 to 127 and its starting slot from 1 to 512 Ne...

Page 9: ...password is only applied after clicking the Submit button The Name page allows you to adjust the name of the E8ANL DIN It provides both a long name and a short name and both are visible on the Status...

Page 10: ...ne option and click Submit the green SIGNAL LED will blink on and off and the selected output will be set to full 10 V If the first output is selected the MIMIC 1 LED will also be illuminated Selectin...

Page 11: ...l loss configuration to determine its signal loss behavior When removed the Hold Last Look function is selected This overrides the Signal Loss setup option JP2 With JP2 installed the E8ANL DIN operate...

Page 12: ...ch of the eight analog outputs carry a 10 mA rating The DMX512 output is made via direct wiring to the 3 position pluggable Phoenix terminal block Limited Manufacturer s Warranty Products manufactured...