Appendix B Cabling JBODs B-7
Caution –
Physical drive IDs are set based on the cabling on the array when it is
powered up. If you are switching from single-bus mode to split-bus mode or from
split-bus mode to single-bus mode, the physical drive IDs change after you power off,
change the cabling, and then power on. If you change physical drive IDs on the array,
ensure that your application points to the correct IDs.
B.6
Cabling a Split-Bus, Multi-Initiator JBOD
Configuration
There are two important features to note with the split-bus, multi-initiator JBOD
configuration:
■
The lower input ports on the JBOD must be terminated with an HBA host
connection or external terminator. The upper I/O SCSI connectors are auto-
terminated.
■
In a split-bus configuration, the physical drive ID numbers automatically change
according to the cabling.
Multi-initiator mode has more than one host connection on a SCSI channel.
Figure B-4 shows a multi-initiator, split-bus configuration where each host is
connected to each host channel. This configuration is common for failover protection
in a network cluster environment.
When you remove one or more host cables for maintenance purposes, insert an
external terminator into each empty port to maintain the physical drive IDs for the
active host connections.
Note –
The I/O module is hot-serviceable, which means that you can replace it or
change its cables while the array is powered on, but the SCSI host buses connected to
the array must be inactive.
Summary of Contents for SANnet II 200
Page 32: ...3 4 SANnet II 200 SCSI Array Installation Operation and Service Manual June 2005...
Page 64: ...4 32 SANnet II 200 SCSI Array Installation Operation and Service Manual June 2005...
Page 74: ...5 10 SANnet II 200 SCSI Array Installation Operation and Service Manual June 2005...
Page 106: ...7 22 SANnet II 200 SCSI Array Installation Operation and Service Manual June 2005...
Page 130: ...B 20 SANnet II 200 SCSI Array Installation Operation and Service Manual June 2005...
Page 146: ...E 10 SANnet II 200 SCSI Array Installation Operation and Service Manual June 2005...
Page 154: ...F 8 SANnet II 200 SCSI Array Installation Operation and Service Manual June 2005...
Page 160: ...G 6 SANnet II 200 SCSI Array Installation Operation and Service Manual June 2005...
Page 178: ...I 10 SANnet II 200 SCSI Array Installation Operation and Service Manual June 2005...
Page 180: ...J 2 SANnet II 200 SCSI Array Installation Operation and Service Manual June 2005...
Page 186: ...6 SANnet II 200 SCSI Array Installation Operation and Service Manual June 2005...