B-6
SANnet II 200 SCSI Array Installation, Operation, and Service Manual • June 2005
Figure B-3
Split-Bus Single-Initiator JBOD Configuration
Split-bus, single-initiator mode: physical drive IDs are 8 to 13 on each channel. In the
following table, A and B indicate the two host channels. The table shows the IDs
assigned to each channel in the split-bus configuration.
Note –
If you want to have IDs of 0 to 5 and plan to add host connections to the upper
two ports later, you can put external terminators into the upper two ports and preserve
the IDs 0 to 5 for the life of the JBOD. For more information, refer to the
SANnet II
Family FRU Installation Guide
.
B.5.1
Connecting a Split-Bus JBOD to One Host
To connect a split-bus JBOD, perform the following steps.
1. Stop any I/O on the host bus that will have a cable installed on the bus.
2. Connect each JBOD port to a host.
Caution –
The lower input ports of the JBOD must have a host connection or external
terminator to maintain SCSI bus integrity.
Caution –
Before you disconnect a cable from the array, the host bus on that cable
must be inactive.
Table B-3
Physical Drive IDs for a Split-Bus JBOD in Single-Initiator Mode
Channel A ID 8
Channel A ID 11
Channel B ID 8
Channel B ID 11
Channel A ID 9
Channel A ID 12
Channel B ID 9
Channel B ID 12
Channel A ID 10
Channel A ID 13
Channel B ID 10
Channel B ID 13
Host
Connections
Host
Auto-terminated upper
each bus)
For IDs 0-5 on each bus,
use external terminators
in empty ports
ports (IDs 8 to 13 on
Summary of Contents for SANnet II 200
Page 32: ...3 4 SANnet II 200 SCSI Array Installation Operation and Service Manual June 2005...
Page 64: ...4 32 SANnet II 200 SCSI Array Installation Operation and Service Manual June 2005...
Page 74: ...5 10 SANnet II 200 SCSI Array Installation Operation and Service Manual June 2005...
Page 106: ...7 22 SANnet II 200 SCSI Array Installation Operation and Service Manual June 2005...
Page 130: ...B 20 SANnet II 200 SCSI Array Installation Operation and Service Manual June 2005...
Page 146: ...E 10 SANnet II 200 SCSI Array Installation Operation and Service Manual June 2005...
Page 154: ...F 8 SANnet II 200 SCSI Array Installation Operation and Service Manual June 2005...
Page 160: ...G 6 SANnet II 200 SCSI Array Installation Operation and Service Manual June 2005...
Page 178: ...I 10 SANnet II 200 SCSI Array Installation Operation and Service Manual June 2005...
Page 180: ...J 2 SANnet II 200 SCSI Array Installation Operation and Service Manual June 2005...
Page 186: ...6 SANnet II 200 SCSI Array Installation Operation and Service Manual June 2005...