88
Environmental requirements and specifications
Electrical requirements
Site wiring and power requirements
Each enclosure has two power supply modules for redundancy. If full redundancy is required, use a
separate power source for each module. The AC power supply unit in each power supply module is
auto-ranging and is automatically configured to an input voltage range from 88–264 VAC with an input
frequency of 47–63 Hz. The power supply modules meet standard voltage requirements for both U.S. and
international operation. The power supply modules use standard industrial wiring with line-to-neutral or
line-to-line power connections.
Power cable requirements
Each enclosure ships with two power cables designed for use with the enclosure power supply module. AC
power cords ship with enclosures equipped with AC power supply modules. Each power cable connects
one of the power supply modules to an independent, external power source. To ensure power redundancy,
connect the two power cables to two separate circuits; for example, to one commercial circuit and one
uninterruptible power source (UPS).