background image

1.

  Remove the cap from meter

2.

 

 Press 

ON/OFF

 button

3. 

 Press and hold 

HOLD/MODE

 until the setting shows 

mS

 at 

     the top left of your meter. 

NOTE:

 This is the 2nd setting 

     from the left

4. 

 Open one ready-to-use liquid calibration packet (CP-1000). 

     

NOTE:

 If using the C1000 calibration solution, you will 

     

need to fill a small cup to submerge the tip of the meter

5.

  Submerge the tip of the meter into the CP-1000 packet of 

     calibration solution

6.

  

Press and hold 

TEMP/CAL

 while tip is submerged until it 

     

begins flashing, then release

7.

  Using arrow keys, adjust the meter until it reads 

2.0

 then 

     press 

ON/OFF

NOTE:

 The meter will start flashing 

     

C…CA…CAL 

when calibrating

8.

 

 When flashing

 stops meter should read 

2.0

 

    

 Your meter is calibrated and ready to use

COM-100 (EC Meter)

How to Calibrate Your Meters

 

COM-80 (EC Meter)

1.

  Remove the cap from meter

2.

 

 Press 

POWER/ENTER

 button

3. 

 Press and hold 

HOLD/MODE

 until the setting 

     shows 

mS

 at the bottom right

4. 

 Open one ready-to-use liquid calibration packet (CP-1000). 

     

NOTE:

 If using the C1000 calibration solution, you will need to fill a small cup 

     to submerge the tip of the meter

5.

  Submerge the tip of your meter into the CP-1000 packet of calibration solution

6.

  Press and hold 

TEMP/CAL

 while submerged until it begins flashing, 

 

     then release

7.

  Using arrow keys, adjust the meter until it reads 

2.0

 then press  

     

POWER/ENTER

NOTE:

 The meter will start to 

flashing 

C…CA…CAL

  

     when calibrating 

8.

  

When flashing

 stops meter should read 

2.0 

 

     

Your meter is calibrated and ready to use

Once your meter is calibrated:

1.

  

Press 

ON/OFF

 to turn your meter on

2.

  

Make sure your meter is set to the 

mS

 setting

3.

  

Submerge the tip into a cup with clear water and record the reading

4.

  

Remove meter from water and shake excess water off

5.

  

Submerge meter in a cup with fertilizer solution and record the reading

6.

  

Take the recorded reading in step 3 (clear water EC) and subtract it from the reading you  

     recorded in step 5 (fertilizer solution EC)

7.

  

The result is the amount of fertilizer in the output

8.

  

Compare this result to the back of your fertilizer bag 

     

NOTE:

 You should compare the result to the value in the 

EC Value

 column for desired PPM

Checking EC (for COM-80 and COM-100)

Calibration 

Solution

CP-1000