Congratulations on your new Dosatron.
Please read the following important information.
QUICK START UP
IMPORTANT NOTES
For complete information on the features and operations,
refer to your Manual on www.dosatron.com
or download our DOSATRON app
NEED HELP ?
Contact your DOSATRON distributor for service or parts
CAUTION
- When connecting a DOSATRON either to the
public water supply or to its own water source, you
must respect the regulations in force concerning
protection of the source i.e. backflow prevention, etc.
- Contact local authorities for requirements of
backflow prevention.
- When installing, operating, and maintaining the
DOSATRON water powered metering pump, keep
safety considerations foremost. Use proper tools,
protective clothings, and eye protection when
working on the equipment and install the equipment
with a view toward ensuring safe operation.
- Follow the instructions in the manual and take
additional safety measures appropriate to the liquid
being pumped and the temperature of the water that
powers the DOSATRON. Be extremely careful in the
presence of hazardous substances (e.g. corrosives,
toxins, solvents, acids, caustic, flammables, etc.).
- Before applying any aggressive chemicals, please
consult your distributor to confirm compatibility with
the dosing pump.
Hand tighten. No tools needed.
This document does not form a contractual engagement on the part of Dosatron International
and is for
information only. Dosatron International reserves the right to alter product specification
or appearance
without prior notice.
© DOSATRON INTERNATIONAL S.A.S
2019
DOSATRON INTERNATIONAL S.A.S.
Certified QEH&S System
Rue Pascal - B.P. 6 - 33370 TRESSES (BORDEAUX) - FRANCE
Tel. 33 (0)5 57 97 11 11
Fax. 33 (0)5 57 97 11 29 / 33 (0)5 57 97 10 85
[email protected] - www.dosatron.com
CUSTOMER SER
VICE - (WORLDWIDE - EUROPE)
Manufactured by
ET398/QSU/D9-06-22
RECOMMENDATIONS
DO NOT USE THIS UNIT WITHOUT A 60 MICRON
[300 MESH] WATER FILTER*
OR YOUR WARRANTY WILL BE VOID.
*The 60 micron [300 mesh] water filter (sold separately)
protects your unit from debris in the water that causes
scoring to the piston and housing.
KNOW YOUR WATER FLOW!
GRADUALLY TURN ON THE WATER.
COUNT THE NUMBER OF CLICKS IN
15 SECONDS. DO NOT EXCEED 44* CLICKS.
CLICK CHART
Clicks/15 sec
l/h
gpm
4
820
3,6
8
1640
7,2
16
3280
14,5
32
6500
29
40
8000
36
44
9000
40
MAXIMUM PRESSURE 8 bar [116 psi]
D9 - 9 m
3
/h - 40 US gpm
D9