2. Tap button (3).
ð
The menu with measured values of the
motor is displayed.
3. Tap button (2).
ð
The menu with measured values of the
pump is displayed.
Enlarge curves
4. Tap button (1).
ð
The “Zoom factor” window is opened.
Fig. 67: Zoom factor (example)
Measured values in the “Pump” window.
Flow rate [l/min]
Supply pipe pressure [bar]
Measured values in the “Motor” window.
Torque [Nm]
Rotational speed [Hz]
5. Enter the enlargement of the curve in the fields
(1) and (2).
6. Exit the window again using the button (3).
8.9
System monitoring
Personnel:
System operator
1. Use the button
to open the “Plant moni-
toring” menu.
Fig. 68: System monitoring
1 Operating hours [h]
2 Energy consumption [Wh]
3 Double strokes
4
“Reset”
button.
Use the button (4) to reset all values of the system
monitoring to zero.
8.10
Alarm history
Personnel:
System operator
1. Open the alarm history using the button
.
Fig. 69: Alarm history
1 Number of the alarm group
2 Number of the alarm within the alarm group
3 Alarm texts
4 Date and time of the alarm event
Alarm history is limited.
Alarm messages are limited to 500
entries.
– Old alarm messages are overwritten.
Colors of messages
Faults are highlighted in red.
Warnings are highlighted in yellow.
Notes are highlighted in white.
Visualizer
05/2017
EcoPUC MC - MCU00003EN