9.3.2 Replace flat jet control
Personnel:
Operator
+ additional qualification high tension
technology
+ additional qualification explosion pro-
tection
Protective equipment:
Protective workwear
Anti-Static Safety Boots
Requirements:
Disassembly
Fig. 32: Disassemble valve
1. Open valve (1).
2. Unscrew and remove the valve (1) with
the supplied open-end wrench (included
in the tool kit).
Fig. 33: Replace O-ring of valve
3. Replace O-ring (2).
Assembly
4. Lightly grease new O-ring (2).
5. Insert and tighten valve (1).
Faults
11/2019
EcoGun AS MAN EC - MSG00022EN