Operating Manual
© Dürr Systems AG
90 / 156
EcoBell2 SL EC - Rotating Atomizer with External Charging
Cleaning and maintenance
Document No.: MRA00001EN
Version:: 07
•
As of:: 01/2020
7.4.3.1
Atomizer body
A T T E N T I O N
Risk of damage to property and production disruption
Damage to body parts
Do not use an ultrasonic bath to clean body parts.
Cleaning in an ultrasonic bath causes micro-cracks on welds, which
as a function of temperature, exposure, and detergent dissolve the
weld. Clean only by hand with a brush, cleaning cloths, and
compressed air.
Do not clean plastic parts in the ultrasonic bath!
Fig. 36: Cleaning the atomizer body
A T T E N T I O N
Risk of damage to property and production disruption
The atomizer body can loosen.
Cleaning motions should be carried out in the direction of rotation of
the thread of the atomizer body, not the other way.
• Wipe atomizer body with a damp cloth back to front.
7.4.3.2
Shaping air ring
Fig.37: Cleaning the shaping air ring
• Clean the outer surface of the shaping air ring.