Operating Manual
© Dürr Systems AG
104 / 156
EcoBell2 SL EC - Rotating Atomizer with External Charging
Cleaning and maintenance
Document No.: MRA00001EN
Version:: 07
•
As of:: 01/2020
7.5.3.1
Removing the electrodes
C A U T I O N
Sharp tip of the electrode
Danger of superficial skin injuries.
Only touch sides of the housing and not needle tip. Wear protective
hand gloves.
• Unscrew the electrode in counterclockwise direction from the
electrode ring.
• Remove the sealing ring from the thread of the electrode.
7.5.3.2
Installing the electrodes
• Screw the new electrodes with sealing rings in a clockwise
direction into the electrode ring. Use minimal force.
The electrode must be flush.
• Electrode and electrode ring must be cleaned with isopropyl
alcohol after the installation.
Pos: 52 /INP/ Bell2/07_05_04 Zgh ab an_AA @ 57\mod_1511775109726_20.docx @ 623163 @ 3445 @ 1
7.5.4
Dismounting and mounting atomizer body
The atomizer body is screwed on at the upper edge of the valve block.
The atomizer body and the shaping air ring are firmly interconnected.
If the shaping air ring is worn out or damaged, the whole atomizer
body must be replaced.
The atomizer body must be unscrewed from the atomizer in order to
carry out the following tasks:
- Cleaning the shaping air ring
- Replacing atomizer body
To work on the interior components, first remove the entire atomizer
from the flange package. Carry out all subsequent works in the
workshop. Remove atomizer body only in the workshop.
7.5.4.1
Dismantling the atomizer body
Once the atomizer is detached from the flange, it can be attached to
the assembly support. The assembly support is clamped in a vise.
• Unscrewing the bell disk
See chapter “Bell Disk Assembly”.