background image

851-312 Rev. C

Setup, Operation

& Maintenance Manual

Industrial and Sanitary 

Variable Speed VFD Controllers

Table of Contents

Warnings – General Safety

2

. . . . . . . . . . . . . . . . . . . . 

Introduction

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Specifications

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Installation

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Required Tools

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Sanitary Controller Mounting

4

. . . . . . . . . . . . . . . . 

Industrial Controller Mounting

4

. . . . . . . . . . . . . . . 

2100, 2200 & 3100 Conveyor Mounting

5

. . . . . . 

6100 Conveyor Mounting

5

. . . . . . . . . . . . . . . . . 

Aluminum Stand Leg Mounting

6

. . . . . . . . . . . . 

Steel Stand Leg Mounting

7

. . . . . . . . . . . . . . . . . 

Wiring

7

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Preventative Maintenance & Adjustment

8

. . . . . . . . . . . 

Required Tools

8

. . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Controller Setup

8

. . . . . . . . . . . . . . . . . . . . . . . . . . . 

Service Parts

 8

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Return Policy

10

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Summary of Contents for 62MV1122

Page 1: ...duction 2 Specifications 3 Installation 4 Required Tools 4 Sanitary Controller Mounting 4 Industrial Controller Mounting 4 2100 2200 3100 Conveyor Mounting 5 6100 Conveyor Mounting 5 Aluminum Stand Leg Mounting 6 Steel Stand Leg Mounting 7 Wiring 7 Preventative Maintenance Adjustment 8 Required Tools 8 Controller Setup 8 Service Parts 8 Return Policy 10 ...

Page 2: ...ation of conveyors Taking protective measures is the responsibility of the user When conveyors are used in conjunction with other equipment or as part of a multiple conveyor system CHECK FOR POTENTIAL PINCH POINTS and other mechanical hazards before system start up Introduction IMPORTANT Some illustrations may show guards removed Do NOT operate equipment with out guards Upon receipt of shipment D ...

Page 3: ... Grip K M6 x 16 mm Stainless Steel Hex Head Cap Screws 2x L Stainless Steel Mounting Clips 2x F I G H J Specifications Dorner Model Number Input Voltage Phase Output Voltage Phase Output Frequency Maximum Hp kW Maximum Output in Amperes Enclosures Manufacurer s Model Number 62MV1122S 115 230Single Phase 0 5 0 37 2 2 M1105SE 62MV1124S 115 Single Phase 10 to 60 Hz NEMA 4x 62MV2124S 230 Single Phase ...

Page 4: ...emoving guards or performing maintenance Figure 2 B E C A D Installation Component List A Sanitary VFD Controller B 6100 Series Accessory Mounting Clips 2x 450186M C Controller Mounting Bar 2x 450333MS D Hex Head Screws M5 x 8mm 4x E Hex Head Screws M6 x 16mm 2x 1 Install mounting clips B of Figure 3 on conveyor Figure 3 B B 2 Attach mounting bars C of Figure 4 to controller A with screws D Figure...

Page 5: ... x 8 mm 4x I Socket Head Screws M6 x 20 mm 2x J T Bars 2x 639971M K Socket Head Screws M6 x 25 mm 2x L Spring Nut M6 2x 990605M M Controller Mounting Bar 2x 300459M 2100 2200 3100 Conveyor Mounting 1 Attach mounting bars M of Figure 7 to controller F with screws H M Figure 7 H H H F 2 Install T bars J of Figure 8 in 2100 Series 2200 Series or 3100 Series conveyor T slots Figure 8 J J 3 Attach cont...

Page 6: ...nstall T bar J of Figure 14 into stand leg T slot Attach controller lower mounting bar N with screw I Figure 14 J N I 3 Temporarily tighten screw I Install second T bar J of Figure 15 into T slot J Figure 15 I 4 With screwdriver O of Figure 16 raise T bar J to align it with hole in top mounting bar Insert M6 screw I and partially thread into T bar Figure 16 J O I I 5 Slide controller to its desire...

Page 7: ...ming maintenance Controller must be properly grounded Failure to properly ground control box may cause injury to personnel Ç Ç Ç Ç NOTE A circuit breaker or a disconnect switch with fuses must be provided in accordance with the Na tional Electrical Code NEC and all local codes Refer to the AC Tech MC1000 Series Installation and Operating Manual shipped with your controller See the sections from AC...

Page 8: ...her than listed refer to the AC Tech MC1000 Series Installation and Operating Manual shipped with your controller See Specifications table for model When purchased with a gearmotor Dorner configures Variable Speed VFD Controllers as follows D 1 second acceleration time D 1 second deceleration time D Minimum frequency 10 Hz for Sanitary units 6 Hz for Industrial units D Maximum frequency 60 Hz D Ov...

Page 9: ...Variable Speed VFD Controllers Setup Operation Maintenance Manual Dorner Mfg Corp 9 851 312 Rev C Notes ...

Page 10: ...se order must be issued Credit if any is issued only after return and evaluation is complete Dorner has representatives throughout the world Feel free to contact Dorner for the name of your local representative Our technical sales and service staff will gladly help with your questions on Dorner products For a copy of Dorner s Limited Warranty contact factory distributor service center or visit our...