Fig. 24
180
5
0
m
in
.
8
ø
SVI 2000
SVI 2000F
SVI 4000
SVI 5000
Recesses and pre-drilled holes in the door leaf for
wiring
4.3.3 Prepare the floor for the masking
plate
Variant
X mm
PHA 2122-0 (0 mm)
26.5
PHA 2122-2 (2 mm)
24.5
PHA 2122-4 (4 mm)
22.5
Fig. 25
80
53
26
45
23.5
X
33
60
Recesses for the masking plate
Fig. 26
±2
60
33
ø 26
Recess for an adjustable masking plate (optional)
4.3.4 Prepare the door frame for the rod
striking plate
Fig. 27
80
21/25
61
13
3
41
20
Recesses for the rod striking plate
4.3.5 Prepare the door leaf for the switch
lock
Fig. 28
55
42
21/25
3
42
ø20
90°
Recesses for the switch lock
4.3.6 Prepare the door leaf for the lower
rod guide
Fig. 29
61
21
40
20
ø16
14
3
Recesses for the lower rod guide
14
SVI Lock
2019-12
dormakaba Mounting instructions
Mounting
WN 059741 45532