SIO-DR

Mounting instructions

About this document

1.1  Contents and purpose

This document describes the mounting of the SIO-DR 
module.

1.2  Target group 

This document is intended for assembling technicians 
and specialists authorized for mounting by 
dormakaba.

1.3  Other applicable documents

•  Instructions for devices intended for networking

1.4  Symbols used

1.

2.

Sequence of action steps

6

Reference to a chapter

Components may be damaged by 
electrostatic discharge. Ground 
your own body before touching a 
component!

2  Safety

2.1  Intended use

The SIO-DR module is used to connect analog switch 
contacts to the dormakaba system bus. Messages are 
output via contacts or control signals are read in.

2.2  Personnel qualification

Mounting may only be carried out by persons 
authorized by dormakaba. 

3  Product description 

The SIO-DR module is a DCW® component. Status 
messages are output potential-free via relays. Control 
signals are read in via optocouplers. 
The mounting takes place on a 35 mm DIN rail in 
a housing. The housing must at least meet the 
requirements of IP 30. 

3.1  Parts included

106

92

65

Contents

About this document 

1

2 Safety 

1

Product description  

1

4 Mounting 

2

Disassembly and disposal 

4

Summary of Contents for SIO-DR

Page 1: ...efore touching a component 2 Safety 2 1 Intended use The SIO DR module is used to connect analog switch contacts to the dormakaba system bus Messages are output via contacts or control signals are read in 2 2 Personnel qualification Mounting may only be carried out by persons authorized by dormakaba 3 Product description The SIO DR module is a DCW component Status messages are output potential fre...

Page 2: ...ormation Supply voltage 24 V DC 15 Power consumption Quiescent current Relay For each active relay the current consumption increases by approx 11 mA 7 mA Relay 1 active 18 mA Relay 1 2 active 29 mA Relay 1 2 3 active 40 mA Relay 1 2 3 4 active 51 mA Ambient temperature 10 C to 55 C Rel humidity up to 93 non condensing Protection class dependent on the housing used Inputs In 1 to In 4 optocoupler C...

Page 3: ... 4 are assigned to the corresponding door addresses 1 to 4 X504 Out 3 Out 4 Contact load capacity 24 V 1 A Contact load capacity 24 V 1 A Emergency button pressed Locked X506 In 1 In 2 Optocoupler 5 28 V AC DC Optocoupler 5 28 V AC DC Temporary unlocking Ü1 Long term unlocking Ü1 Parameterizable via TMS Soft In multi door systems In 1 to In 4 are assigned to the corresponding door addresses 1 to 4...

Page 4: ...osal Disassembly is carried out in the reverse order of mounting and must be carried out by qualified personnel The product must be disposed of in an environmentally friendly manner Electro technical parts and batteries must not be disposed of as domestic waste Dispose of electrotechnical parts and batteries in the designated acceptance and collection points Refer to the statutory regulations for ...

Reviews: