Mounting instructions

About this document

1.1  Content and purpose 

This document describes the mounting of the SCU-DR 
and the connection to a SafeRoute® system.

1.2  Target group 

This document is intended for assembling technicians 
and specialists authorized to carry out installation by 
dormakaba.

1.3  Other applicable documents

The following documents belong to the unit’s 
complete documentation and must be observed: 
•  The SafeRoute® system manual
•  The respective door unit’s inspection log
•  The approved components’ declaration of 

conformity

1.4  Documents storage 

This document must be handed over to the facility 
operator after mounting and commissioning.

1.5  Symbols used

1.

2.

Sequence of action steps

6

Reference to a chapter

Components may be damaged by 
electrostatic discharge. Ground 
your own body before touching a 
component!

2  Safety

2.1  Intended use

The SCU-DR controls the SafeRoute® electrical 
locking system from dormakaba. 

2.2  Personnel qualification

Mounting may only be carried out by persons 
authorized by dormakaba. 

3  Product description 

The SCU-DR is a DCW® component for controlling 
escape route doors. The SCU-DR must be installed on 
a 35 mm DIN rail in a housing. The housing must at 
least meet the requirements of IP 30. 
The inserted license card turns the SCU-DR into a 
SafeRoute® Control Unit in a SafeRoute® escape route 
security system.

3.1  Parts included

•  SafeRoute® Control Unit SCU-DR

3.2  Technical information

Supply voltage:

24 V DC +/- 15 %

Power consumption:

30 mA

Ambient temperature:

-10 °C to +55 °C

Protection class:

Dependent on housing

Inputs  
In 1 to In 4

Current consumption of 
inputs per input:
at   5 V  AC/DC:  3 mA
at   12 V  AC/DC:  8 mA
at  24 V  AC/DC:  17 mA
at  28 V  AC/DC:  28 mA

Outputs 
Out 1 to Out 2

For each active relay, 
the current consumption 
increases by approx. 
12 mA

Contact load capacity: 

24 V, 1 A

Contents

About this document 

1

2 Safety 

1

Product description  

1

4 Mounting 

2

Disassembly, recycling and disposal 

4

Summary of Contents for SCU-DR

Page 1: ...d use The SCU DR controls the SafeRoute electrical locking system from dormakaba 2 2 Personnel qualification Mounting may only be carried out by persons authorized by dormakaba 3 Product description The SCU DR is a DCW component for controlling escape route doors The SCU DR must be installed on a 35 mm DIN rail in a housing The housing must at least meet the requirements of IP 30 The inserted lice...

Page 2: ...card optional Battery optional 1 2 1 4 2 Assignment of terminals and switch button S601 S600 In 1 In 2 In 3 In 4 GND 24V 1 A B 3 Out 1 Out 2 Out 3 Out 4 GND 24V DCW BAT USB SLI Service GND Mode1 AS Sabo Rx Tx Mode2 GND 1G 1 AS Sabo GND Tx Rx GND X500 X504 X502 X402 X506 X510 X507 X400 NO C NC NO C NC NO C NC NO C NC GND 24V GND 24V In 1 In 2 In 3 In 4 1 A B 3 ...

Page 3: ...act load capacity 24 V 1 A Contact load capacity 24 V 1 A X506 In 1 In 2 Optocoupler 5 28 V AC DC Optocoupler 5 28 V AC DC Default Static control Default Static control Parameterizable via TMS Soft For multi door systems In 1 to In 4 are assigned to the corresponding door numbers 1 to 4 X510 In 3 In 4 Optocoupler 5 28 V AC DC Optocoupler 5 28 V AC DC Default Static control Default Static control T...

Page 4: ...ith inserted license card No node configured Configuration mode active Operation License error 4 4 Complete mounting 1 Document the mounting and commissioning in the inspection log 2 Hand over this document to the facility operator 5 Disassembly recycling and disposal Disassembly is carried out in the reverse order of mounting and must be carried out by qualified personnel The product must be disp...

Reviews: