dormakaba USA Inc. System User Guide 7040.1121 Rev E 10/22 | 19
4.
Select Between “On” and “Off” to Enable/Disable Buzzer Mode.
5.
“Success Mode updated” will appear on screen and the Keypad will beep twice and flash a green LED once
complete.
3.3.3.2 Buzzer Mode – Non-Display Keypad
Follow these steps to toggle the Buzzer Mode On and Off on a non-Display Keypad:
1.
Using the Keypad, input #41 + Authorized User ID and Combi Off (0) or On (1) + <return key> (←).
2.
The Keypad will beep and flash a green LED three times once complete.
WARNING:
Once the Buzzer Mode has been turned off, there will be no audible signals for successful or
unsuccessful commands.
3.3.4 Combination Length
The Combination Length can be changed to a length between 6 and 9 digits inclusively. This feature can only be
modified by a Master user. This feature only applies to non-Master users. A Master combination is always 8
digits. By default, the combination length for non-Master users is 6 characters.
WARNING:
If the combination length is changed after any users have been entered into the system, those users
will need to reset their combination before they can perform any operations. After a user’s combination is reset,
the user will then need to change their combination again in order to use the system. Since the Master User is
the only one whose combination is unaffected by change in Combination length, the Master must reset other
users’ combinations. Once a Manager’s Combination is reset and then changed again, the Manager can reset
other users’ combinations.
3.3.4.1 Combo Length – Display Keypad
Follow these steps to change the combination length on a Display Keypad:
1.
Enter an Authorized User ID and Combination.
2.
Navigate through the Main Menu and select “Combination”.
3.
Select “Combo Length” from the sub-menu.
4.
Input the # of Digits with the Keypad. Confirm the selection with the <return key> (←). For UL
certification, the combination must be a minimum of 6 digits long.
5.
The Keypad will ask for Confirmation, “Are you sure?”. Select Yes.
6.
“Success Length updated” will appear on screen and the Keypad will beep three times and flash a green
LED once complete.
3.3.4.2 Combo Length – Non-Display Keypad
Follow these steps to change the combination length on a non-Display Keypad:
1.
Using the Keypad, input #11 + Master User ID and Combi Digit Length (from 6 – 9) + <return key>
(←).
2.
The Keypad will beep three times and flash a green LED once complete.
3.3.5 Force Change Combination
The Force Change Combination setting is a security rule that, when enabled, forces Manager and Standard
users to change their combination prior to first use.