84
ED50
08-2018
DL4614-140
dormakaba ED50 OHC Installation Instructions
Chapter 32
32.1 Customer supplied doors - double door installation
32 Double door installation
Fig. 32.1.1 Double door inswing example; ready for door installation
1
Overhead arm
rotated to 70
degrees or greater
2
Floor pivot
NOTICE
Door, jambs, and finger guards by customer.
Door installation:
Customer responsibility.
WARNING
Door installation must meet ANSI/BHMA
standards as well as any applicable local
building codes.
Fig. 32.1.2 Hanging doors
32.1.1 Conditions prior to installing doors.
1. Overhead arms rotated to 700 open position or
greater.
2. Floor pivots installed by customer.
CAUTION
Jamb edge to floor pivot centerline distance:
3 3/4". Reference Chapter 14, Installation
Template, Para. 14.2.
3. ED50 OHC operator axle to floor pivot plumb
checked for both doors (Chapter 25).
4. Bottom pivot hardware installed in floor by customer
for both doors.
32.1.2 Hang doors - reference single door installation.
1. Reference steps in Paragraph 30.5, single door to
hang each door.
Fig. 32.1.3 Doors closed after doors hung
2
2
1
1