background image

CS 80 MAGNEO 

Automatic sliding door operator

Installation and Troubleshooting 
Manual

DL3316-020 – 10-2022

EN

 | 

Summary of Contents for CS 80 MAGNEO

Page 1: ...CS 80 MAGNEO Automatic sliding door operator Installation and Troubleshooting Manual DL3316 020 10 2022 EN ...

Page 2: ...2 2 Required tools 30 3 Important installation instructions 31 4 Safety instructions 32 5 Functional Characteristics 34 6 System overview 36 7 Before mounting 37 8 Installation instructions for on wall mounting 40 8 1 Mounting procedure 40 9 Installation instructions in wall mounting 48 9 1 Installation instructions 48 10 Connection diagrams 54 11 Cable channel 55 12 Connection of closing edge pro...

Page 3: ...ed uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his her expense 1 1 5 Symbols used in these instructions WARNING ...

Page 4: ...Clear DS3300 01B MAGNEO ON WALL w MANET 875 DB Dark bronze DS3300 010 MAGNEO ON WALL w MANET 875 ML Mill DS3300 02A MAGNEO ON WALL w MANET 1000 CL Clear DS3300 02B MAGNEO ON WALL w MANET 1000 DB Dark bronze DS3300 020 MAGNEO ON WALL w MANET 1000 ML Mill DS3300 03A MAGNEO ON WALL w MANET 1125 CL Clear DS3300 03B MAGNEO ON WALL w MANET 1125 DB Dark bronze DS3300 030 MAGNEO ON WALL w MANET 1125 ML Mi...

Page 5: ... on edge cover kit MAGNEO 1 1 1 8 DK3306 010 Screwdriver kit not shown 1 1 1 7 DK3299 01G Kit Floor guide 1 1 1 6 DK3297 030 On wall mounting kit MAGNEO 1125 mm 1 6 DK3297 020 On wall mounting kit MAGNEO 1000 mm 1 6 DK3297 010 On wall mounting kit MAGNEO 875 mm 1 5 DK3293 01G MANET kit MAGNEO 1 1 1 4 DK3289 01_ End cap set 62 mm MAGNEO 1 1 1 3 DK0109 001 Kit Label MAGNEO 1 1 1 2 DE3291 01X Extrusi...

Page 6: ... ON WALL w Wood 875 DB Dark bronze DS3300 040 MAGNEO ON WALL w Wood 875 ML Mill DS3300 05A MAGNEO ON WALL w Wood 1000 CL Clear DS3300 05B MAGNEO ON WALL w Wood 1000 DB Dark bronze DS3300 050 MAGNEO ON WALL w Wood 1000 ML Mill DS3300 06A MAGNEO ON WALL w Wood 1125 CL Clear DS3300 06B MAGNEO ON WALL w Wood 1125 DB Dark bronze DS3300 060 MAGNEO ON WALL w Wood 1125 ML Mill Table 1 3 1 MAGNEO ON WALL a...

Page 7: ...kit not shown 1 1 1 7 DK3303 010 Solid door floor guide kit 1 1 1 6 DK3297 030 On wall mounting kit MAGNEO 1125 mm 1 6 DK3297 020 On wall mounting kit MAGNEO 1000 mm 1 6 DK3297 010 On wall mounting kit MAGNEO 875 mm 1 5 DK3295 010 Wood door mounting and guide rail 1125 mm 1 1 1 4 DK3289 02_ End cap set 75 mm MAGNEO 1 1 1 3 DK0109 001 Kit Label MAGNEO 1 1 1 2 DE3291 01X Extrusion cover 75 mm 2336 1...

Page 8: ... WALL w Clamp 875 DB Dark bronze DS3300 070 MAGNEO ON WALL w Clamp 875 ML Mill DS3300 08A MAGNEO ON WALL w Clamp 1000 CL Clear DS3300 08B MAGNEO ON WALL w Clamp 1000 DB Dark bronze DS3300 080 MAGNEO ON WALL w Clamp 1000 ML Mill DS3300 09A MAGNEO ON WALL w Clamp 1125 CL Clear DS3300 09B MAGNEO ON WALL w Clamp 1125 DB Dark bronze DS3300 090 MAGNEO ON WALL w Clamp 1125 ML Mill Table 1 4 1 MAGNEO ON W...

Page 9: ...kit not shown 1 1 1 9 DK3299 01G Floor guide kit 1 1 1 8 DK3297 030 On wall mounting kit MAGNEO 1125 mm 1 7 DK3297 020 On wall mounting kit MAGNEO 1000 mm 1 7 DK3297 010 On wall mounting kit MAGNEO 875 mm 1 6 DK3294 03_ Clamp rail kit 1125 mm 1 5 DK3294 02_ Clamp rail kit 1000 mm 1 5 DK3294 01_ Clamp rail kit 875 mm 1 4 DK3289 02_ End cap set 75 mm MAGNEO 1 1 1 3 DK0109 001 Kit Label MAGNEO 1 1 1 ...

Page 10: ... No Description Finish DS3301 01A MAGNEO ON GLASS w MANET 875 CL Clear DS3301 01B MAGNEO ON GLASS w MANET 875 DB Dark bronze DS3301 010 MAGNEO ON GLASS w MANET 875 ML Mill DS3301 02A MAGNEO ON GLASS w MANET 1000 CL Clear DS3301 02B MAGNEO ON GLASS w MANET 1000 DB Dark bronze DS3301 020 MAGNEO ON GLASS w MANET 1000 ML Mill DS3301 03A MAGNEO ON GLASS w MANET 1125 CL Clear DS3301 03B MAGNEO ON GLASS ...

Page 11: ...t kit 1000 mm 1 10 DK3311 02G MAGNEO On Glass mount kit 1000 mm 1 9 DK3311 01G MAGNEO On Glass mount kit 875 mm 1 8 DK3307 010 Snap on Edge Cover Kit MAGNEO 1 1 1 7 DK3306 010 Screwdriver kit not shown 1 1 1 6 DK3299 01G Kit floor guide 1 1 1 5 DK3293 01G MANET kit MAGNEO 1 1 1 4 DK3289 01 End cap set 62 mm MAGNEO 1 1 1 3 DK0109 001 Kit Label MAGNEO 1 1 1 2 DE3291 01X Extrusion cover 62 mm 2336 1 ...

Page 12: ...ish DS3301 04A MAGNEO ON GLASS w Wood 875 CL Clear DS3301 04B MAGNEO ON GLASS w Wood 875 DB Dark bronze DS3301 040 MAGNEO ON GLASS w Wood 875 ML Mill DS3301 05A MAGNEO ON GLASS w Wood 1000 CL Clear DS3301 05B MAGNEO ON GLASS w Wood 1000 DB Dark bronze DS3301 050 MAGNEO ON GLASS w Wood 1000 ML Mill DS3301 06A MAGNEO ON GLASS w Wood 1125 CL Clear DS3301 06B MAGNEO ON GLASS w Wood 1125 DB Dark bronze...

Page 13: ...On Glass mount kit 1000 mm 1 9 DK3311 01G MAGNEO On Glass mount kit 875 mm 1 8 DK3307 010 Snap on Edge Cover Kit MAGNEO 1 1 1 7 DK3306 010 Screwdriver kit not shown 1 1 1 6 DK3303 010 Wood door floor guide kit 1 1 1 5 DK3295 010 Wood door mounting and guide rail 1125 mm 1 1 1 4 DK3289 02 End cap set 75 mm MAGNEO 1 1 1 3 DK0109 001 Kit Label MAGNEO 1 1 1 2 DE3291 01X Extrusion cover 62 mm 2336 1 2 ...

Page 14: ...GLASS w Clamp 875 DB Dark bronze DS3301 070 MAGNEO ON GLASS w Clamp 875 ML Mill DS3301 08A MAGNEO ON GLASS w Clamp 1000 CL Clear DS3301 08B MAGNEO ON GLASS w Clamp 1000 DB Dark bronze DS3301 080 MAGNEO ON GLASS w Clamp 1000 ML Mill DS3301 09A MAGNEO ON GLASS w Clamp 1125 CL Clear DS3301 09B MAGNEO ON GLASS w Clamp 1125 DB Dark bronze DS3301 090 MAGNEO ON GLASS w Clamp 1125 ML Mill Table 1 7 1 MAGN...

Page 15: ...Glass Mount kit 1000 mm 1 10 DK3311 01G MAGNEO On Glass Mount kit 875 mm 1 9 DK3307 010 Snap on edge cover kit MAGNEO 1 1 1 8 DK3306 010 Screwdriver kit not shown 1 1 1 7 DK3299 01G Kit Floor guide 1 1 1 6 DK3294 03_ Clamp rail kit 1125 mm 1 5 DK3294 02_ Clamp rail kit 1000 mm 1 5 DK3294 01_ Clamp rail kit 875 mm 1 4 DK3289 02_ End cap set 75 mm MAGNEO 1 1 1 3 DK0109 001 Kit Label MAGNEO 1 1 1 2 D...

Page 16: ...LL w MANET 875 DB Dark bronze DS3302 010 MAGNEO IN WALL w MANET 875 ML Mill DS3302 02A MAGNEO IN WALL w MANET 1000 CL Clear DS3302 02B MAGNEO IN WALL w MANET 1000 DB Dark bronze DS3302 020 MAGNEO IN WALL w MANET 1000 ML Mill DS3302 03A MAGNEO IN WALL w MANET 1125 CL Clear DS3302 03B MAGNEO IN WALL w MANET 1125 DB Dark bronze DS3302 030 MAGNEO IN WALL w MANET 1125 ML Mill Table 1 8 1 MAGNEO IN WALL...

Page 17: ...260 M10 Box 14 1 2 x 2 7 8 x 4 1 4 1 1 1 8 DL3316 010 Instruction MAGNEO mounting 1 1 1 7 DK3415 010 MAGNEO floor guide 1 1 1 6 DK3306 010 Screwdriver kit not shown 1 1 1 5 DK3299 01G Kit Floor guide 1 1 1 4 DK3296 In wall mounting kit MAGNEO 1 1 1 3 DK3293 01G MANET kit MAGNEO 1 1 1 2 DK0109 001 Kit Label MAGNEO 1 1 1 1 DD4613 030 Logo plate ESA slide 1 1 1 Part Assembly Description 01X QTY 02X Q...

Page 18: ...IN WALL w WOOD 875 DB Dark bronze DS3302 040 MAGNEO IN WALL w WOOD 875 ML Mill DS3302 05A MAGNEO IN WALL w WOOD 1000 CL Clear DS3302 05B MAGNEO IN WALL w WOOD 1000 DB Dark bronze DS3302 050 MAGNEO IN WALL w WOOD 1000 ML Mill DS3302 06A MAGNEO IN WALL w WOOD 1125 CL Clear DS3302 06B MAGNEO IN WALL w WOOD 1125 DB Dark bronze DS3302 060 MAGNEO IN WALL w WOOD 1125 ML Mill Table 1 9 1 MAGNEO IN WALL wi...

Page 19: ...16 1 1 1 8 DP3260 M10 Box 14 1 2 x 2 7 8 x 4 1 4 1 1 1 7 DL3316 010 Instruction MAGNEO mounting 1 1 1 6 DK3306 010 Screwdriver kit not shown 1 1 1 5 DK3303 010 Solid door floor guide kit 1 1 1 4 DK3296 In wall mounting kit MAGNEO 1 1 1 3 DK3293 01G MANET kit MAGNEO 1 1 1 2 DK0109 001 Kit Label MAGNEO 1 1 1 1 DD4613 030 Logo plate ESA slide 1 1 1 Part Assembly Description 04X QTY 05X QTY 06X QTY Ta...

Page 20: ...LL w CLAMP 875 DB Dark bronze DS3302 070 MAGNEO IN WALL w CLAMP 875 ML Mill DS3302 08A MAGNEO IN WALL w CLAMP 1000 CL Clear DS3302 08B MAGNEO IN WALL w CLAMP 1000 DB Dark bronze DS3302 080 MAGNEO IN WALL w CLAMP 1000 ML Mill DS3302 09A MAGNEO IN WALL w CLAMP 1125 CL Clear DS3302 09B MAGNEO IN WALL w CLAMP 1125 DB Dark bronze DS3302 090 MAGNEO IN WALL w CLAMP 1125 ML Mill Table 1 10 1 MAGNEO IN WAL...

Page 21: ...1 8 DL3316 010 Instruction MAGNEO mounting 1 1 1 7 DK3415 010 MAGNEO floor guide 1 1 1 6 DK3306 010 Screwdriver kit not shown 1 1 1 5 DK3299 01G Kit floor guide 1 1 1 4 DK3296 In wall mounting kit MAGNEO 1 1 1 3 DK3294 03_ Clamp rail kit 1125 mm 1 3 DK3294 02_ Clamp rail kit 1000 mm 1 3 DK3294 01_ Clamp rail kit 875 mm 1 2 DK0109 001 Kit Label MAGNEO 1 1 1 1 DD4613 030 Logo plate ESA slide 1 1 1 P...

Page 22: ...3303 01B MAGNEO ON CEILING w MANET 875 DB Dark bronze DS3303 010 MAGNEO ON CEILING w MANET 875 ML Mill DS3303 02A MAGNEO ON CEILING w MANET 1000 CL Clear DS3303 02B MAGNEO ON CEILING w MANET 1000 DB Dark bronze DS3303 020 MAGNEO ON CEILING w MANET 1000 ML Mill DS3303 03A MAGNEO ON CEILING w MANET 1125 CL Clear DS3303 03B MAGNEO ON CEILING w MANET 1125 DB Dark bronze DS3303 030 MAGNEO ON CEILING w ...

Page 23: ...1 9 DK3415 010 MAGNEO floor guide 1 1 1 8 DK3306 010 Screwdriver kit not shown 1 1 1 7 DK3299 01G Kit Floor guide 1 1 1 6 DK3296 In wall mounting kit MAGNEO 1 1 1 5 DK3293 01G MANET kit MAGNEO 1 1 1 4 DK3289 01_ End cap set 62 mm MAGNEO 1 1 1 3 DK0109 001 Kit Label MAGNEO 1 1 1 2 DE3292 01X Extrusion cover 75 mm 2336 1 2 DE3292 01X Extrusion cover 75 mm 2086 1 2 DE3292 01X Extrusion cover 75 mm 18...

Page 24: ... w WOOD 875 DB Dark bronze DS3303 040 MAGNEO ON CEILING w WOOD 875 ML Mill DS3303 05A MAGNEO ON CEILING w WOOD 1000 CL Clear DS3303 05B MAGNEO ON CEILING w WOOD 1000 DB Dark bronze DS3303 050 MAGNEO ON CEILING w WOOD 1000 ML Mill DS3303 06A MAGNEO ON CEILING w WOOD 1125 CL Clear DS3303 06B MAGNEO ON CEILING w WOOD 1125 DB Dark bronze DS3303 060 MAGNEO ON CEILING w WOOD 1125 ML Mill Table 1 12 1 MA...

Page 25: ... 1 8 DK3306 010 Screwdriver kit not shown 1 1 1 7 DK3303 010 Solid door floor guide kit 1 1 1 6 DK3296 In wall mounting kit MAGNEO 1 1 1 5 DK3293 01G WOOD DOOR mounting and guide rail 1125 mm 1 1 1 4 DK3289 02_ End cap set 75 mm MAGNEO 1 1 1 3 DK0109 001 Kit Label MAGNEO 1 1 1 2 DE3292 01X Extrusion cover 75 mm 2336 1 2 DE3292 01X Extrusion cover 75 mm 2086 1 2 DE3292 01X Extrusion cover 75 mm 183...

Page 26: ...AMP 875 DB Dark bronze DS3303 070 MAGNEO ON CEILING w CLAMP 875 ML Mill DS3303 08A MAGNEO ON CEILING w CLAMP 1000 CL Clear DS3303 08B MAGNEO ON CEILING w CLAMP 1000 DB Dark bronze DS3303 080 MAGNEO ON CEILING w CLAMP 1000 ML Mill DS3303 09A MAGNEO ON CEILING w CLAMP 1125 CL Clear DS3303 09B MAGNEO ON CEILING w CLAMP 1125 DB Dark bronze DS3303 090 MAGNEO ON CEILING w CLAMP 1125 ML Mill Table 1 13 1...

Page 27: ...1 8 DK3306 010 Screwdriver kit not shown 1 1 1 7 DK3299 01G Floor guide kit 1 1 1 6 DK3296 In wall mounting kit MAGNEO 1 1 1 5 DK3293 01G Clamp rail kit 1125 mm 1 5 DK3293 01G Clamp rail kit 1000 mm 1 5 DK3293 01G Clamp rail kit 875 mm 1 4 DK3289 02_ End cap set 75 mm MAGNEO 1 1 1 3 DK0109 001 Kit Label MAGNEO 1 1 1 2 DE3292 01X Extrusion cover 75 mm 2336 1 2 DE3292 01X Extrusion cover 75 mm 2086 ...

Page 28: ...DK3296 010 MAGNEO fixing set In wall mounting Fig 1 14 4 DK3297 0x0 MAGNEO ON WALL mount kit Ref Para 1 3 1 6 1 9 1 12 Ref Para 1 2 1 5 1 8 1 11 Ref Para 1 8 1 9 1 10 Ref Para 1 2 1 3 1 4 Fig 1 14 5 DK3298 0x0 MAGNEO ON WALL shim kit Ref Para 8 1 7 Fig 1 14 6 DK3299 01_ MAGNEO glass floor guide kit Ref Para 1 2 1 5 1 10 1 11 1 13 Fig 1 14 7 DK3303 01_ MAGNEO solid door floor guide kit Ref Para 1 3...

Page 29: ...t lock kit w jamb prep Fig 1 14 11 DK3306 010 Screwdriver kit Fig 1 14 12 DK3307 010 Snap on edge covers kit wall connection Ref Para 1 2 1 3 1 4 1 5 1 6 1 7 Fig 1 14 13 DK3308 0xG MAGNEO vertical pull handle kit Fig 1 14 14 DK3309 01G MAGNEO recessed door grip Fig 1 14 15 DK3311 0x0 MAGNEO on glass mount kit Ref Para 1 5 1 6 1 7 Fig 1 14 16 DK3361 010 MANET thru hole fitting Fig 1 14 17 DK3415 01...

Page 30: ...truct the owner in the safe use of the door The owner must also be presented with the CS 80 MAGNEO Owner s Manual and to carefully explain how to perform the daily safety check list Each step of the installation adjustment and instructions are important for proper and safe use of the door being installed If there are any questions about any items contained in these instructions call the local dorm...

Page 31: ...and Low Energy Power Operated Swing Doors A156 38 Standard for Low Energy Power Operated Sliding and Folding Doors 7 After installation the door must be adjusted to conform with dormakaba recommendations and all code requirements Carefully study the requirements in these instructions 8 After installation and adjustment the installer s final responsibility is to properly instruct the owner in the s...

Page 32: ...rotection measure is optional and lies in the discretion of the person performing the installation of the door system under consideration of the result of the individual risk assessment Special spatial conditions and certain user groups might make it sensible to equip the application with safety sensor even when the system is operated in the Low Energy Mode Whether this is required or not has to b...

Page 33: ...perator should always held level No water or liquids must drop onto or into the CS 80 MAGNEO To avoid electric shocks never insert metal objects inside the openings of the CS 80 MAGNEO To avoid injuries never put your hand inside the CS 80 MAGNEO Lay the power cord so that no one can trip over the cable or unplug it by mistake Do not operate the CS 80 MAGNEO when the power cord is damaged Always p...

Page 34: ...s well The door speed is infinitely variable within limits using the potentiometer located inside the operator Even though the door may open at a fast speed the closing cycle always remains in the Low energy mode 5 4 Operation modes OFF The operator is switched off The door can be manually moved AUTOMATIC When the system is activated by pushbutton radio remote control or other similar devices the ...

Page 35: ...closing it will immediately stop and perform an opening cycle 5 7 Safety sensors Sensors can be installed to detect obstacles An automatic sensor test can be activated or deactivated via the DIP switches located inside the operator Opening cycle The door will stop immediately when the sensor detects an obstacle during an opening cycle and will continue the cycle as soon as the object has been remo...

Page 36: ...lug will only fit in a grounding type outlet If the plug does not fit in the outlet contact a qualified electrician to install the proper outlet Do not modify the plug in any way 8 7 6 5 4 3 2 1 N O 1 2 3 4 5 6 7 8 Fig 6 2 CS 80 MAGNEO control unit Part Assembly Description 1 DIP switch 2 LED indicator green yellow red 3 Potentiometer hold open time 4 Terminals connections for external accessories...

Page 37: ... are always located on the side where the door is when it is in the closed position The operator is symmetrical and can be turned as required for the installation The installation instructions show the system with the connection on the right side For left hand reverse the orientation of the operator 7 3 Assistance If additional accessories are required or if there are technical questions please co...

Page 38: ...stallation with permanent power supply The internal power supply socket must be removed Proceed as follows Fig 7 3 1 Loosen the screws at end stop 2 Move end stop to center of the system CAUTION Do not remove or tighten the end stop 7 7 Remove the power supply housing cover Fig 7 4 1 Loosen screw in cover of power supply housing 2 Remove cover on the side where the connections are located TIPS AND...

Page 39: ...7 9 Remove internal socket 1 Loosen screws of the connection terminals and remove the internal shockproof socket 7 10 Close cover of control unit housing secure end stop Fig 7 7 1 Close cover to the control unit 2 Move the end stop to the end of the channel 3 Tighten end stop screws CAUTION The end stop must overlap Fig 7 5 Control unit cover opening Fig 7 6 Socket removal Fig 7 7 Control unit cov...

Page 40: ...osing edge Fig 8 1 4 34 4 875 39 4 1000 44 3 1125 C 22 7 575 27 6 700 32 5 825 L 68 9 1750 78 7 2000 88 6 2250 M 17 2 437 5 19 7 500 22 1 562 5 TIPS AND RECOMMENDATIONS In case the door panel is not positioned in the center of the passage the bracket or shim plate must be shifted by the desired dimension Fig 8 1 1 Glass door panels with MANET single point attachment M Main closing edge Reference l...

Page 41: ...00 22 1 562 5 NOTICE Dimension X When using a Wooden door panel X door panel height 3 78 mm When using a glass clamping rail X door panel height 4 1 2 114 mm When using dormakaba MANET single point fixings X door panel height 2 29 32 74 mm 8 1 4 Mark upper edge of attachment bracket 1 Mark the upper edge of the attachment bracket onto the wall The closed position is always located on the side wher...

Page 42: ...ach side CAUTION When installing the angle bracket use adequate wall plugs and screws depending on the prevailing structure The supplied screws and wall plugs are suitable for concrete and brickwork 4 Recheck angle bracket for exact positioning 5 Drill additional holes through the drill holes in the angle bracket and secure the bracket with a minimum of 12 screws Fig 8 1 7 8 1 6 Uneven walls 1 In ...

Page 43: ... Drill the marked holes and attach the shim plate CAUTION When installing the attachment bracket use adequate wall plugs and screws depending on the prevailing structure The supplied screws and wall plugs are suitable for concrete and brickwork CAUTION The load bearing capacity of the shim plate must be a minimum of 528 lb 239 5 kg 8 1 8 Door frame thicker than 3 8 9 5 mm Distance plates enclosed ...

Page 44: ...supply 4 Reference Para 8 1 12 for grounding wire connection 8 1 11 Conduit connection When using a conduit connection use the supplied conduit cover mounting plate and Phillips screws 1 Attach mounting plate to operator with 2 screws 2 Route the wires through the mounting plate and connect to the operator 3 Fold the conduit cover as shown 4 Secure conduit cover to mounting plate with remaining sc...

Page 45: ...d tighten end stop screws Ref Chapter 7 Fig 7 7 8 1 15 Install panel 1 Insert panel into door panel suspension 2 Align panel so that it is parallel to wall and secure it with fasteners 8 1 16 Door panel to wall maximum distance NOTICE The distance between the door panel and wall must not exceed 5 16 7 94 mm 1 2 3 1 2 3 Fig 8 1 16 Close and secure cover move and secure end stop Fig 8 1 17 Panel ins...

Page 46: ...nce between the bottom edge of the door panel and the floor should be 1 4 6 35 mm The distance must not exceed 5 16 7 94 mm 8 1 19 Secure end stop at desired door closed position 1 Loosen the end stop screws on the side where the connections are made 2 Move the door to the desired position 3 Move end stop next to the door panel and tighten the end stop fasteners NOTICE The end stop may only be mov...

Page 47: ...e cut to length or broken out at predetermined breaking points 8 1 22 Install accessories and route cables into operator 1 Install radio receivers program switch and or sensors or other accessories 2 Route cables as indicated in the enclosed instructions 8 1 23 Install power plug if used 1 Plug in power supply cord if used 8 1 24 Install cover 1 Install the 4 supplied pieces of foam rubber at equa...

Page 48: ... mm m m 5 7 5 9 2 Fig 9 1 1 Minimum recess in wall mounting Table 9 1 1 Installation dimensions L 68 9 1750 mm 78 7 2000 mm 88 6 2250 mm M 17 2 437 5 mm 19 7 500 mm 22 1 562 5 mm A 73 6 min 1750 mm min 83 5 min 2120 mm min 73 6 min 2370 mm min C 22 7 575 mm 27 6 700 mm 32 5 825 mm A minimum L 4 72 120 mm L 2 min 50 mm min 2 75 min 70 mm min Bottom edge of header 2 75 min 70 mm min C Centered M Clo...

Page 49: ...nstall bracket with suitable screws 9 1 5 Align operator at mounting bracket location 1 Move operator over mounting bracket as far as it will go TIPS AND RECOMMENDATIONS Operator orientation Position operator correctly i e the side with the connections must be opposite the mounting bracket Para 9 1 4 CAUTION Never leave operator on mounting bracket without holding it in position otherwise the brac...

Page 50: ...The side with the connections must be opposite the attachment bracket Para 9 1 4 CAUTION Never leave operator on attachment bracket without holding it in position otherwise the attachment bracket would be deformed TIPS AND RECOMMENDATIONS Openings of door panel suspension must point to the front as they cannot be turned following installation of the system 9 1 8 Install operator to cross girder 1 ...

Page 51: ...Fold the conduit cover as shown 4 Secure conduit cover to mounting plate with remaining screw 9 1 11 Grounding wire PE connection to power supply 1 Using a screwdriver open the control unit housing cover 2 Route the grounding wire through the operator control unit housing and connect it to the grounding terminal PE WARNING The grounding wire must be connected to the PE terminal 9 1 12 Connection o...

Page 52: ... not exceed 5 16 7 94 mm 9 1 15 Install panel 1 Insert panel into door panel suspension 2 Align panel so that it is parallel to wall and secure it with fasteners Fig 9 1 13 Panel installation 9 1 14 Place door panel inside door frame 1 Move end stop to end of channel CAUTION End stop must not fall out of operator 2 Place door inside door frame As door panel is wider than the doorway the panel will...

Page 53: ... end stop in door open position 1 Loosen opposite side end stop screws 2 Move door to desired open position 3 Move end stop next to door panel 4 Tighten end stop screws NOTICE The end stop may only be moved to the outside by a maximum dimension Y 34 4 875 mm operator 7 9 200 mm 39 4 1000 mm operator 9 5 250 mm 48 2 1125 mm operator 11 8 300 mm 3 2 1 Y 4 Y Fig 9 1 17 End stop final position 9 1 19 ...

Page 54: ... 3 1 3 15 3 13 1 3 42 3 31 3 34 1 3 11 3 13 1 3 41 3 not assigned Locking device Locking device 27 V DC GND Automatic GND Permanent open 27 V DC GND GND Safety sensor test 27 V DC GND GND Safety sensor test 27 V DC GND GND 27 V DC GND GND Program switch optional Remove jumper before program switch is installed Safety sensor for secondary closing edge Remove jumper before sensor is installed Safety...

Page 55: ...tallation and Troubleshooting Manual Chapter 11 Fig 11 1 Wire routings in cable channel 11 Cable channel Cables for external accessories sensors pushbuttons etc must be routed inside the cable channel as shown in Fig 11 1 2 50 mm 0 250 6 mm ...

Page 56: ...d the control unit has to be configured to the sensors via the DIP switches Main closing edge sensor connection Set DIP switch 1 to ON and DIP switch 2 to OFF Secondary closing edge sensor connection Set DIP switch 1 to ON and DIP switch 3 to OFF Sensors connected to both main and secondary closing edges Set DIP switch 1 to ON and DIP switches 2 and 3 to OFF Fig 12 1 1 Control unit DIP switch 8 7 ...

Page 57: ...ming a new commissioning 13 3 Learning cycle 1 In order to start the learning cycle The door must be open The operator must be switched on The movement range of the door must be free of obstacles The LED will blink green before the first learning cycle 2 Press and hold the Reset button for more than 3 seconds NOTICE Do not interrupt the learning cycle as the system currently learns all of the valu...

Page 58: ...ated ON Internal pushbutton activated 3 OFF Test low active ON Test high active 2 OFF Sensortest at secondaryclosing edge deactivated ON Sensortest at secondaryclosing edge deactivated 1 OFF Sensor test at main closing edge deactivated ON Sensor test at main closing edge deactivated Table 6 3 DIP switch settings Fig 13 1 3 DIP switch 13 5 Permanent Open function by double click This function can o...

Page 59: ... button is pushed a second time or the door is manually moved the door will close 8 7 6 5 4 3 2 1 ON 8 7 6 5 4 3 2 1 ON 14 4 Express function The door can be moved manually into its driving direction without extra resistance When maximum speed is exceeded the operational resistance will increase in line with the speed by which it is exceeded As soon as the user releases the door panel the operator...

Page 60: ...witch if supplied is installed on the lateral cover on the side with the door in the closed position 14 8 1 Changing the operating mode 1 To change the operating mode set the program switch to the desired position 14 9 Operating cycle indicator When the Reset button Fig 13 1 2 is momentarily depressed the door will open In case the LED light indicator illuminates for one second yellow light the sy...

Page 61: ...per function Effective safety equipment if installed to avoid or protect danger spots between certain parts of the door system and between the door and its structural environment for example safety clearances or the protection of the secondary closing edge Inspection and maintenance work has been documented 15 2 Maintenance work NOTICE Power to the CS 80 MAGNEO must be turned OFF and secured again...

Page 62: ...ve obstacles Adjust safety sensors if required Damaged sensor cable Check and replace cables if required Check and replace jumpers if required No safety sensors are connected Terminals must be bridged The operator is defective Replace operator The green LED light indicator blinks at certain intervals The learning cycle has not been properly performed Restart learning cycle Chapter 13 The operator ...

Page 63: ...ng width is incorrectly adjusted Readjust opening width end stops Start learning cycle Chapter 13 The red LED blinks 6 times at regular intervals There is an obstacle within the door s movement range Remove obstacles from movement range The opening width is incorrectly adjusted Readjust opening width end stops Start learning cycle Chapter 13 The red LED blinks 10 times at regular intervals Stator ...

Page 64: ...x 36 ft2 1 2 glass Max 27 ft2 A 5 Power requirements A 115 Vac 50 60 Hz 15 A max 14 AWG per operator A 6 Standards of compliance A UL 325 CSA 22 2 listed with ETL B Designed to comply with these standards depending on installation and application International Building Code Section 1008 ANSI BHMA 156 10 Requires additional overhead activation and safety sensors ANSI BHMA 156 38 Requires additional...

Page 65: ...MIN RECESSED DOOR GRIP OPTIONAL 5 7 8 150 36 914 CLEAR OPENING WIDTH SHOWN 84 2134 CLEAR OPENING HEIGHT SHOWN DOOR PANEL WIDTH CLEAR OPENING WIDTH 5 127 L C OPERATOR DETAIL LEFT HAND SLIDE OPEN DOOR SHOWN MIRROR FOR RIGHT HAND SLIDE OPEN EQUAL SPACING FRONT ELEVATION LEFT HAND SLIDE OPEN DOOR SHOWN OPERATOR LENGTH 9 1 8 232 CENTER BRACKET LOCATION END BRACKET LOCATION LOCATE THE OPERATOR BY ALIGNI...

Page 66: ...9 5 3 4 145 11 16 17 3 32 2 ADJUSTMENT 3 32 3 ADJUSTMENT SHIM SPACER 5 16 8 MAX BOTTOM GUIDE 2 1 16 52 RECESSED DOOR GRIP OPTIONAL DOOR PANEL DETAIL 3 8 10 1 2 13 SOLID TEMPERED GLASS GRIP HEIGHT 41 1 8 1045 2 15 32 63 2 5 32 55 MANET MOUNTS 1 1 4 32 TYP 1 26 TYP 90 TYP COUNTERSUNK GLASS HOLES ON THIS SIDE 1 2 13 OPERATOR LENGT MUST BE PLUMB AND LEVEL 84 2134 CLEAR OPENING HEIGHT SHOWN Fig A 2 MAG...

Page 67: ...E OPEN DOOR SHOWN AS CLOSED FIXED PANEL MOUNTS CRITICAL DIMENSION REFER TO CHART 41 1 8 1045 RECESSED DOOR GRIP OPTIONAL DOOR PANEL HEIGHT CLEAR OPENING HEIGHT 1 4 6 DOOR PANEL WIDTH CLEAR OPENING WIDTH 5 127 Ø 1 1 4 32 COUNTERSINK TYP Ø 1 26 TYP 5 127 SHOWN 2 3 4 70 MIN Ø 2 1 16 52 EQUAL EQUAL 2 15 32 63 2 5 32 55 PANEL IS VIEWED AS FLIPPED FROM FRONT ELEVATION WITH COUNTERSINK UP LEADING EDGE OF...

Page 68: ...MENSION REFER TO CHART 41 1 8 1045 RECESSED DOOR GRIP OPTIONAL DOOR PANEL HEIGHT CLEAR OPENING HEIGHT 1 4 6 Ø 1 1 4 32 COUNTERSINK TYP Ø 1 26 TYP 5 127 SHOWN 2 3 4 70 MIN 2 15 32 63 2 5 32 55 Ø 2 1 16 52 EQUAL FRONT ELEVATION RIGHT HAND SLIDE OPEN DOOR SHOWN AS CLOSED EQUAL DOOR PANEL WIDTH CLEAR OPENING WIDTH 5 127 PANEL IS VIEWED AS FLIPPED FROM FRONT ELEVATION WITH COUNTERSINK UP LEADING EDGE O...

Page 69: ... Glass width varies among header lengths D Glass must be solid tempered Operator Length Fixed Panel Mounts MinimumPanel Width 68 90 1750 22 64 575 30 762 78 74 2000 27 56 700 35 39 899 88 58 2250 32 48 825 39 33 999 Table A 2 MAGNEO symmetrical panel 3 8 GLASS MAX 36 ft 1 2 GLASS MAX 27 ft DOOR PANEL HEIGHT DOOR PANEL WIDTH Fig A 6 MAGNEO symmetrical panel A 9 Recessed door grip Fig A 7 Recessed d...

Page 70: ...losing edge and possible injury caused by the breakage of glass during mounting corresponding protective clothing especially gloves and protective goggles are required 4 Before mounting the glass fitting clean clamping area with fat solvent standard commercial cleaning agent 5 Never use clamping shoes on structured glass surfaces except on satined glass or glass of heavily varying thickness unless...

Page 71: ...ass clamping areas must be cleaned with standard glass cleaning products prior to installation CAUTION Do not use thinners Fig B 2 1 Sliding door and wall Sliding door Wall Fig B 2 2 Glass preparation Recessed pull grip scope of delivery Ø 38 m m 1 3 4 Preassembled Fig B 2 3 Preparation of the recessed pull grip 1 1 1 3 1 2 1 4 1 1 2 2 2 1 Fig B 2 4 Recessed pull grip installation 80052 228 632 ...

Page 72: ...st be cleaned with standard glass cleaning products prior to installation CAUTION Do not use thinners Fig B 3 1 Glass clamping area Fig B 3 3 Preparation of recessed pull grip Fig B 3 2 Recessed pull grip scope of delivery Preassembled for 10 12 mm glass Setscrew for 8 mm glass is enclosed 1 1 1 1 1 2 1 3 2 1 2 2 1 2 Fig B 3 4 Recessed pull grip installation 2 2 Tighten by hand With 8 mm of glass ...

Page 73: ...ns for use of operator must be observed C 2 Mounting NOTICE Preparation of mounting 1 Determine closed position 2 Mount drive unit 3 Attach door panel and move door to closed position C2 1 Overview Removing end stop attachment screws and end stop 1 Carefully pull out carrier until the attachment screws of the stop are visible 2 Remove end stop screws remove end stop Reference Para C2 2 through C2 ...

Page 74: ...urther than required to access stop attachment screws STOP Fig C2 2 End stop C2 3 Removing stop attachment screws and stop 1 Remove screws in Fig C2 3 and the stop Fig C2 3 Stop and attachment screws 1 2 3 2 C2 4 Install new plastic bracket with lock bolt 1 Insert plastic bracket with lock bolt 2 Use the 4 supplied countersunk holes to secure the bracket to the carrier 3 Push carrier back into tra...

Page 75: ...1 95 96 94 95 96 1 3 not assigned Locking device Locking device 27 V DC GND Optional MAGNEO locking device Connector Locking cable 94 95 96 1 3 Fig C2 5 Locking cable wiring diagram 96 95 1 GRN BRN WHT 96 95 1 GRN BRN WHT Fig C2 5b Locking cable routing Fig C2 5c Locking cable routing Fig C2 5d Locking cable terminal installation 96 95 1 GRN BRN WHT ...

Page 76: ...t drive unit attach door panel and move to closed position 1 Mount drive unit 2 Attach door panel 3 Move door panel until it reaches the selected closed position 4 Check if carrier and locking device are flush C2 9 Push carrier back into position and secure 1 Push carrier back into position 2 Screw down with the supplied special key C2 10 Secure connection cable to track rail 1 Secure connection c...

Page 77: ...able External activator 1 e g radar motion detector pushbutton External activator 2 e g radar motion detector pushbutton Internal activator 1 e g radar motion detector pushbutton Internal activator 2 e g radar motion detector pushbutton Activator cable Activator cable WH YE GN BN WH YE GN BN WH YE GN BN WH YE GN BN WH YE GN BN WH YE GN BN 27 VDC GND GND 27 VDC GND GND 27 VDC GND GND 27 VDC GND GND...

Page 78: ... set for safety sensor D 1 Turn power switch OFF Fig D 1 Power switch OFF D 2 Remove end caps 1 Use flat blade screwdriver to unsnap cover from operator 2 Remove cover Fig D 2 End caps removal 1 2 Fig D 3 Cover removal D 3 Remove cover 1 Use flat blade screwdriver to unsnap cover from operator 2 Remove cover ...

Page 79: ...ower side D 4 Sensor installation Use drill template supplied by sensor manufacturer Fig D 4 Sensor installation on cover D 5 Sensor wiring routing Reference sensor manufacturer wiring documentation and Fig C3 2 for wiring D 6 Cover with sensor installation Fig D 5 Sensor wiring routing on cover Fig D 6 Sensor and cover installation ...

Page 80: ... Additional set for safety sensor Fig D 7 Sensor installation on cover ACTIV8 ONE ON ArtMotion 1 4 6 mm 2 50 mm D 8 Sensor wiring routing Fig D 8 Sensor wiring routing 3 8 x 3 4 10 x 20 mm If necessary notch end cap in area of cable route D 9 Cover end cap installation Fig D 9 Sensor wiring ...

Page 81: ... Main closing edge Test input GND 24 VDC Green Brown Red Blue Pink Gray Brown Green Pink Blue Gray Red Green Brown Red Blue Pink Gray GND 24 VDC Test input IRIS ON 1 3 15 3 13 1 3 11 3 13 D 11 ACTIV8 sensor wiring Fig D 11 ACTIV8 sensor wiring Brown Green Pink Blue Gray Red GND 24 VDC Opening pulse Test input Main closing edge 1 3 11 3 13 Yellow White 3 1 3 42 Green Brown Yellow White Red Blue Pin...

Page 82: ...12 Art Motion sensor wiring Fig D 12 Art Motion sensor wiring Refer to Art Motion installations instructions for operation instructions External activator Internal activator 24VDC GND Opening pulse Opening pulse 24VDC GND 3 1 41 3 3 1 42 3 Yellow White Brown Green Yellow White Brown Green ...

Page 83: ...en Pink Gray Red Blue Opening pulse 27 VDC GND Output IR Output IR Monitoring Monitoring Opening pulse 27 VDC GND Output IR Output IR Monitoring Monitoring IR IR Internal motion detection and protection of main closing Edge External motion detection and protection of main closing edge D 13 ACTIV8 sensor wiring Fig D 13 ACTIV8 sensor wiring Refer to ACTIV8 installations instructions for operation i...

Page 84: ...nstalled in end cap OFF OFF ON 1 2 Fig E 3 Remove end cap E 2 Remove end cap 1 Put Mode switch in OFF position 2 Remove end cap E 3 Cutout end cap switch cover for switch 1 Use box cutter to cutout end cap switch cover for Mode switch CAUTION Use caution when using box cutter Fig E 4 Cut out end cap for Mode switch E 4 Install Mode switch in end cap cutout Fig E 5 Install Mode switch into end cap ...

Page 85: ...witch installation E 5 Install and terminate program switch wiring 1 Remove jumper between terminals 31 and 3 Discard jumper 2 Install end cap into CS 80 MAGNEO As end cap is installed route program switch wiring to terminal strip 3 Strip 1 4 6 mm of insulation from ends of wires 4 Terminate program switch wiring at terminal strip ...

Page 86: ...www dormakaba us dormakaba USA Inc 1 Dorma Drive Drawer AC Reamstown PA 17567 USA T 717 336 3881 F 717 336 2106 ...