Installation Instructions for Wi-Q™ Technology 45HQ Mortise Locks
BEST
a Product Group of dormakaba USA Inc.
3
Installation Instructions for Wi-Q™ Technology 45HQ Mortise Locks
Configuring & installing the mortise case
2 Feed the wires for the door status switch into the
door status switch hole and through the channel
into the mortise cavity and out through one of the
sensor and motor wire holes.
3 Press fit the door status switch assembly into the
door status switch hole.
5
Rotate latchbolt (if necessary)
Note:
If a function specific mortise case was ordered,
some steps for configuring the case have already been
performed at the factory.
1 Determine whether you need to rotate the latchbolt
to match the handing of the door.
Note:
The angled surface of the latchbolt must con-
tact the strike when the door closes.
2 If you need to rotate the latchbolt, insert a flat blade
screwdriver into the latch access point approxi-
mately 1/2
into the case and press to extend the
latch out of the case. See Figure 4.
3 Rotate the latchbolt 190 degrees (slightly past 180
degrees) and allow it to retract into the case.
6
Position hub toggles (if necessary)
1 Check whether the hub toggles are in the proper
position for the lock. See the table below
and Figure 5.
Note 1:
For LH & LHRB doors, the inside is the back
side of the case and the outside is the cover side of the
case. For RH & RHRB doors, the inside is the cover side
of the case and the outside is the back side of the case.
The cover is mounted to the case with four screws.
Note 2:
Two RQE status switches are installed in the
mortise case. However, only the switch for the inside of
Hub toggle positions
Function
DV, TV
Hub toggle positions
Inside down (always
unlocked) &
outside up (lockable)
Figure 4 Rotating the latchbolt
Latch access point
Hub toggle
Figure 5 Positioning hub toggles
Hub toggle
Summary of Contents for BEST Wi-Q ONGUARD
Page 7: ...A Glossary Glossary 109 B Lock Installation Lock Installation 113 ...
Page 40: ...40 2 Select Inbound Rules Figure 13 Inbound Rules Select Inbound Rules ...
Page 45: ...45 7 De select the Public option Click Next Figure 18 De select Public ...
Page 52: ...52 Figure 27 Wi Q Interface Setup Wizard Click Next ...
Page 57: ...57 Figure 33 Custom Setup Options Click Next ...
Page 75: ...75 To add a new Sign On Credential 1 Select Add Figure 52 Add Segment Sign On Credential 1 ...
Page 113: ...B Lock installation ...