Exit Device Operators 630/750/79E/RT/E7900 Series/ Generation E-730 PK3677_T
10-18
9
CAUTION
WARNING
IMPORTANT
Perform the following procedures in order, with the
door OPEN unless otherwise indicated.
1 Panic Bar
Activate the panic bar. The latch bolt or rod
retracts fully.
2 Outside Lever
Turn the outside lever downward. The latch bolt or
rod does not retract.
If the latch bolt or rod retracts, verify that the bat-
teries are properly installed.
If the lever feels tight (hard to turn, or does not
return easily to its horizontal rest position), check
the spindle length vs. the door thickness (the spin-
dle may be too long). Check that the slotted end of
the spindle is inserted in the lock housing hub, not
the exit device.
3 Electronics and Card Reader
Test the lock’s response to keycards: a Test key-
card, a Grand Master keycard, and an Emergency
keycard.
Insert keycards as shown below, with the magnetic
stripe facing toward the door and to the left. For
79E, present cards to reader.
E Test the operation of the E-730/750/79E lock
(for 630 lock go to Section H) (For RT lock series, please refer to
system 6000 manual)
A Test the Lock Before Programming
Normal Entry: Use the Test keycard with the reader.
The red and green LEDs each flash once and then
the green LED flashes for four seconds.
Turn the outside lever downward while the green
LED is flashing. The latch or rod retracts fully.
Release the lever, then turn it again. The latch or rod
must not retract after the LED stops flashing with-
out first inserting the keycard.
B Lock Programming
Program the lock with its Common Area number
(exit devices are usually programmed as common
areas, see Reference Manual).
Use the Grand Master keycard with the reader. The
green LED flashes. Turn the outside lever down-
ward while the green LED is flashing. The latch or
rod retracts fully and the LED stops flashing after
4 seconds. Release the lever, then turn it again. The
latch or rod must not retract again without first
inserting the keycard.
C Emergency Keycard Access
Use the Emergency keycard with the reader. The
green LED flashes for 4 seconds. Then, turn the
outside lever downward. The latch or rod retracts
fully.
While standing outside the room, close the door and
ensure that it is properly latched. Open the door
using the Grand Master keycard using the same
procedure.