8.1.5 Creating a programmer memory image
The memory image can only be created with the Programmer 1460.
1.
Start the 'EAC Service Tool’ auxiliary program.
2.
Connect the programmer to the computer.
3.
Press the 'Programmer memory image' button.
4.
Follow the Wizard’s instructions.
5.
Select the file name and storage location.
6.
Click on the 'Next' button.
ð
The memory map is created.
7.
Click on the 'Finish' button.
8.2 Emergency supply
The emergency supply is only possible after a "Battery flat" signal.
Emergency opening with the programmer is not possible for the digital cylinder or c-lever
compact.
If all the warnings are ignored and the batteries are now completely flat, doors can no longer
be opened from the outside with the components. All functions are blocked. Only "Batteries
flat" is indicated (acoustic signal three seconds in duration).
The following actuators can still be opened with the programmer and emergency supply:
•
c-lever
•
TouchGo.
Behaviour of the actuators whilst the emergency supply is applied:
•
Actuators remain open
•
Entry "Emergency supply event" written to traceback
•
TimePro is not evaluated.
After the emergency power is applied, always replace the batteries and set the time
accurately so access authorisations with time settings or CardLink remain usable.
1.
Open the Settings menu.
2.
Select the Emergency supply sub-menu.
3.
Press the ENTER button.
4.
Connect the programming cable.
5.
Confirm with ENTER.
ð
The programmer action is displayed.
6.
Hold up an authorised medium.