Doran SCC-AM-00 Installation And Operation Manual Download Page 1

 

 

 

 

SLEEPING CHILD CHECK 

Model SCC-AM-00/01 and 

Model SCC-AM-24V

 

 

 

 

INSTALLATION AND 

 OPERATION MANUAL  

 

Doran Manufacturing LLC 

2851 Massachusetts Ave. 

Cincinnati, Ohio 45225 

(866)-816-7233 TEL 

(513) 681-5604 FAX 

www.doranmfg.com 

 

OCTOBER 2016 

 

Summary of Contents for SCC-AM-00

Page 1: ...CHECK Model SCC AM 00 01 and Model SCC AM 24V INSTALLATION AND OPERATION MANUAL Doran Manufacturing LLC 2851 Massachusetts Ave Cincinnati Ohio 45225 866 816 7233 TEL 513 681 5604 FAX www doranmfg com...

Page 2: ...structions find online at www doranmfg com Electric drill and 5 8 drill bit Test Light Probe 16 or 14 gauge wire Automotive GXL SLX or equivalent Insulated female quick connectors for 250 blades Wire...

Page 3: ...at Rear of Bus GND SCC AM DOME LIGHT OUTPUT IS FUSED FOR 10 AMPS MAXIMUM A RELAY WILL BE REQUIRED FOR CIRCUITS GREATER THAN 10 AMPS BAT P1 GND ACCESSORY POWER V battery LEFT OR RIGHT RED WARNING SIGNA...

Page 4: ...attery V battery ACCESSORY POWER IGNITION V battery Option 3 CONVERSION VANS MINIBUSES DOME LIGHTS SCC AM DOME LIGHT OUTPUT IS FUSED FOR 10 AMPS MAXIMUM A RELAY WILL BE REQUIRED FOR CIRCUITS GREATER T...

Page 5: ...m the battery The fuses on the module protect the relays and the load and also limit current through BAT and BAT But if both fuses are in the NEG position then the sum of load currents flows through P...

Page 6: ...ion the SCC system will require deactivation at the end of the trip See Timer Options for another alternative For testing and trouble shooting when the SCC is in ARMed state the Yellow LED is illumina...

Page 7: ...P1 Battery Make a connection from P1 Bat terminal on the SCC to constant Pos battery voltage With the ignition turned OFF use a test probe to locate a wire with constant positive voltage GROUND P2 Bat...

Page 8: ...nvenient place to connect to the switch may be at the flasher unit which uses the door switch Frt_DOOR is expecting a ground when the door begins to open Frt_DOOR pin P7 may be used if Bat V is presen...

Page 9: ...ease the current capacity See Figure 2 To use this feature you will need to determine how the manual switch activates these lights Find the wire going to the lights from the switch With a test light o...

Page 10: ...SION VANS MINI BUSES W 0 WARNING FLASHERS Use ignition accessory or brake light input at the ARM terminal P6 This usually means the system will need to be reset after any startup Where driver usually...

Page 11: ...Start the school bus Make sure all the doors are closed 2 Activate the Red warning light flashers and open the door The YELLOW LED will light on the circuit board to show the system is armed 3 Turn o...

Page 12: ...quired to be installed please follow the instructions below COMMON COM TERMINAL BRACKET MINATURE SWITCH NORMALLY CLOSED NC TERMINAL ROLLER ARM Figure 5 SCC AM SW 00 Switch Remove the panel above the a...

Page 13: ...Battery Voltage signal on the ARM terminal P6 if it is connected Some states require an additional way to ARM the module for field trips shuttles and other group trips when the warning lights may not...

Page 14: ...ill not warrant the product Selecting Timer Options Jumper JP1 Open cut JP1 for Horn ALARM to be triggered 1 Minute after Ignition Off JP2 Open cut JP2 will ARM module after 10 continuous minutes with...

Page 15: ...en the power is off to the device sometimes the flasher unit will cause this In this case the SCC door input must be isolated from the other device s or a separate door switch or contact must be used...