9
NHM/NHP Series NHM/NHPATCE29
④
Adjust the distance between tool carrier pot and sub changer
Use the gap gauge to measure the distance between centering fixtures as shown, and use
the sub-changer In/Out adjustable stopper to make adjustment.
※
When
adjusting the gap, care must be taken because the gap can be changed due to or as
a result of
"
②
Adjust the horizontal position of the tool carrier pot"
.
※
2mm
is a smallest value. It is advisable to use a 2mm spanner to measure the distance.
※
In most cases where you adjust the position of the sub change and tool carrier pot, you
should make adjustment all together both horizontally and vertically.
2 mm
(BIG PLUS SPINDLE)
Gap adjustable
stopper