DX380LC-7
Operation
3-82
Pump Programming
The working/interval times can be reprogrammed to adapt the
lubrication intervals and the resulting lubricant quantities to
specific requirements.
Start Programming Mode
NOTE:
Programming mode can be identified by the flashing
LED displays.
Change Lubrication Interval Times
NOTE:
If the 000 factory setting has been changed, the
current code must be selected using the
keys
and confirmed using the
key.
Step
Key
Display
1
Press for more than 2s
Display flashes
(000 = factory setting)
2
Press briefly
(confirm code)
Automatic display of first parameter:
"pause in timer operation"
"PAUSE" LED flashes
3
Press briefly
Interval time 1 h (factory setting)
(display in hours)
4
Set new value
Example: 6.8 h = 6 h 48 min.
5
Press briefly
(confirm new value)
Display next parameter
"pump cycle time in timer operation"
"CONTACT" LED flashes
6
Press briefly
Pump cycle time 4.0 min. (factory setting)
Note the operating mode/set duration
(display in minutes)
7
Set new value
Example: 3 min.