2-17
DX380LC-7
Cabin Work Light Switch (If Equipped)
This switch is used to control the cabin work lights, if unit is
equipped with them.
O.
In this position, all cabin work lights are turned "OFF".
I.
In this position, the front cabin work lights on the front top
of cabin will turn "ON".
II.
In this position, the front cabin work lights on the front top
of cabin and rear cabin work lights on rear top of cabin will
turn "ON".
After Treatment System Switch
Used for manual (forced) regeneration or the inhibition (non-
regeneration) of DPF regeneration.
NOTE:
Run machine at "LOW IDLE" and do not stop engine
until regeneration cycle is completed. See "After
Treatment System" on page 3-20, for more
information.
O.
The switch automatically returns to this position when it is
released.
I.
In this position, DPF regeneration is inhibited (non-
regeneration).
The inhibition (non-regeneration) symbol will light up on the
display monitor.
Pressing on the switch to this position when already in DPF
regeneration inhibition (non-regeneration) relieves the
inhibition.
II.
In this position, manual (forced) regeneration is conducted
for the SCR system.
Use this function when the regeneration warning symbol
has lit up on the display monitor.
NOTE:
Turn "OFF" cutoff switch before you start forced
regeneration.
If the machine is moved or stopped while manual
(forced) regeneration is in process, the regeneration
cycle will need to be restarted.
FG016019
O
I
II
Figure 22
FG018280
O
I
II
Figure 23
NOTICE
Move safety lever to "LOCK" position for manual (forced)
regeneration.
If the equipment is moved or switched off while manual
(forced) regeneration is in process, the regeneration will