52
OPERATING INSTRUCTIONS
7/124 - 10/104, 10/124 - 14/114, 14/84
CUSTOM PRESSURE MODE OF OPERATION
Key
A. Separator tank
B. Panel pressure gauge
C. Discharge pressure transducer
D. Automatic blowdown valve
E. Orifice
F. Unloader
G. Start / run solenoid valve
H. Regulator pressure transducer
I. Pressure regulator - Low pressure mode
J. Pressure regulator - High pressure mode (for dual mode models only)
K. Mode solenoid valve (for dual mode models only)
L. Captive pressure solenoid valve
M. Orifice
N. Manual blowdown valve
O. Custom pressure regulator
P. Custom pressure solenoid valve
CUSTOM PRESSURE
This feature allows customer set required pressure independently on
HI/LO mode. The main reason for implementation is to reduce fuel
consumption as much as possible by setting the exact pressure value
required.
The machine is equipped with an additional pressure regulator and
solenoid valve.
Custom pressure activation controls outlet pressure and engine speed.
Settings (described for 7/124-10/110 unit):
Set Custom pressure value between HI/LO mode pressure, e.g 9 bar
and activate function.
Machine operates in HI mode, pressure drops from 10 to 9 bar and
engine speed remains the same.
Machine operates in LO mode, pressure drops to 7 bar (nominal
pressure) and engine speed rises to 2200 rpm.
Switch to HI mode, pressure rises to 9 bar and engine speed drops to
1950 rpm.
T3992B_01
11/16
B
C
D
E
F
O
J
P
G
H
L
M
N
I
K
A
Summary of Contents for 10/104
Page 2: ......
Page 4: ......
Page 11: ...ISO SYMBOLS 7 7 124 10 104 10 124 14 114 14 84 Replace any cracked protective shield ...
Page 83: ...MAINTENANCE 79 7 124 10 104 10 124 14 114 14 84 ...
Page 84: ...80 MAINTENANCE 7 124 10 104 10 124 14 114 14 84 ...
Page 92: ...88 MACHINE SYSTEMS 7 124 10 104 10 124 14 114 14 84 ...
Page 108: ......
Page 109: ......