background image

Installation of Heater

6500-480-

E

-

3

-1

9

DoorKing Part Number

6500-480

Copyright 2011 DoorKing, Inc. All rights reserved.

120 Glasgow Avenue

Inglewood, California 90301 

U.S.A.

Kit Includes:

 Heater and Fan Assembly, mounting plate and mounting bracket, 3 bolts - lockwashers - nuts, 2 heater locknuts.

Heater Locknut

Run 

power wires

through chass

is.

ON

OFF

Heater

and Fan

Assembly

Mounting Bracket

Mounting
Plate

Power Connection

Connect the heater power wires to primary/single 
6500

/6524

 

source 115 VAC

.

To secondary 

operator heater if 

installed.

DANGER

HIGH VOLTAGE!

Heater Switch

Neutral

Hot

115 VAC Models

 Only!

1

2

DANGER

HOT!

Note: Older model 
6500s may need to 
have chassis hole 
drilled for this bolt.

Chassis

Shut off ALL power to operator

Note for Bi-Parting Dual Gate Operators:

 

Run two (AWG 16-600 volt insulation) 
power wires from the 

primary

 operator 

power terminal through the interconnection 
cable conduit to power the secondary 
operator’s heater. 

Do Not

 wire secondary 

heater directly to the secondary operator’s 
terminal or damage will occur.

ON

 - 

Normal setting.

 Automatically turns the heater and

fan 

ON

 when the temperature drops below 40°F (4°C) inside 

the operator, and turns the heater and fan 

OFF

 when the 

temperature rises above 55°F (13°C) inside the operator.

OFF

 - Turns the heater and fan off.

ON

OFF

Keep wires
aw

ay from

the heater
vent.

Power Wires

3 Bolts, Lockwashers
and Nuts

Reviews: