H7 SVR – INSTRUCTIONS 

Page 1 of 4 

 

CONTROLLER MOUNTING: 

The  controller  enclosure  must  be  firmly  attached  to  a  nearby  solid  fixture  by  either  the  two  mounting  lugs  or  direct 
attachment  though  the  controller. If mounting through the controller ensure the power cord is disconnected from the 
mains  supply  then  remove  the  enclosure  front  cover  by  turning  the  four  corner  locks so each arrow points to the ‘O’ 
marked on the front cover. Insert two mounting screws diagonally through the oval holes in the enclosure, refit front 
cover and turn the four corner locks to the ‘I’ position.

 

The

 

power cable is 1.8m long and should be plugged directly into a general power outlet, not into an extension lead. 

 

CIRCULATING PUMP: 

The  circulating  pump  plugs  into  the  right  hand  240Vac  socket  marked  as  PUMP  and  will  be  operating  as indicated by 
the PUMP ON LED. The left hand 240Vac socket marked as Auxiliary provides continuous power as indicated by the AUX 
ON. LED. 

The maximum allowable combined current for both pumps is 10 AMPS @ 2400W.

 

 

HEATER INTERLOCK: 

The heater interlock cable connects to the green socket marked RELAY1 which switches on the NO/C contacts when the 
heater is to be turned on. The other end of the heater interlock cable connects in series (daisy chain) to the heater’s 
flow or pressure switch circuit (refer manufactures instructions). If the heater’s flow/pressure switch circuit is 

240Vac

 

then 

DO

 

NOT

 connect the RELAY1 cable directly to the heater, a H7SV240 controller needs to be used which is 

supplied with an external 240V rated relay which will need to be connected in series with the flow/pressure switch by a 

licensed electrician

. Set the temperature setting on the heater 5°C above the desired water temperature to allow the 

H7 to be in control without conflict.  
 

VALVE: 

The valve actuator is connected to the green socket marked VALVE, wired as described on the label. The valve is used 
for selecting or bypassing the solar collector. 
 

TEMPERATURE SENSORS: 

The  pool  sensor  must  be  fitted  into  the  suction  line  of  the  pump,  preferably  in  a  position  out  of  direct  sunlight.  It  is 
recommended that a 14.5mm hole be drilled in the PVC pipe, this can be carried out using a Dontek PD01 grinding drill 
or a small pilot hole can be drilled and a 14.0mm drill-bit used spinning in a counter clockwise direction to minimize the 
chance of shattering pipe. Insert the grommet into the pipe and gently push in the black sensor barb. The green sensor 
plug is to be fitted to the plug socket marked POOL. 
This  unit  has  been  designed  to  eliminate  the  need  to run a temperature sensor cable from the solar controller to the 
roof, this is replaced by a Solar Powered roof temperature transmitter that only transmits when in direct sunlight, and a 
receiver that calculates the roof and pool temperature turning on the solar pump when required.  
As the unit operates in a UHF radio band, reflections and moving objects can cause a transmission to be corrupted with 
a subsequent indication “ROOF SIGNAL NOT RECEIVED” on the display. Up to 10 transmissions can be missed (and last 
valid reading is kept for 10 minutes) before pump action will occur and the solar pump will turn off. If this occurs, and 
if the solar conditions are still favorable, the solar pump will not turn on again and resume normal operation unless it 
has received a valid transmission. 
The  remote  roof  transceiver  obtains its operating power from a solar panel, it will not operate if there is no sun or if 
there is significant cloud cover. Obviously solar heating would not occur in such conditions. 
Due to the possibility of reception ghosting and electrical interference the Transmitter may be required to be moved to 
an  alternative  position,  this  may  be  as  little  as  two  meters  and  keep  in  mind  that  the  roof  sensor  cable  may  be 
extended 20 meters if required. The main controller should be mounted away from other electrical appliances as far as 
possible  to  reduce  the  chance  of  interference.  If  the  unit  is  to  be  installed  in  a  metal  shed  there  may  be  reception 
issues and the controller may need to be optioned with a remote antenna or moved outside. 

 

DESCRIPTION: 

The H7 SV is a swimming pool controller that heats a swimming pool by the use of an auxiliary heater or if solar gain is 
available an automatic valve will divert water to the solar collectors. 
The auxiliary heater (gas or heat pump) has a temperature limit setting (aux limit), the pool will be heated to this limit 
by the auxiliary heater. 
The auxiliary heater run time is controlled by heat demand settings, which can be set to on/off and set to run between 
start  and  end  times,  note  that  if  the  start  &  end  time  are  set  to  the  same  values  the  auxiliary  heater  will  run  for  24 
hours to achieve temperature limit. 
If solar gain is available the solar system will heat the pool to the solar limit (sol limit). 
Solar has a time lockout that prevents heating outside the hours of 08:00 to 19:00 and can be changed (see note 6). 
An automatic divert valve will divert water to the solar collectors when there is enough solar gain and will revert back 
to the auxiliary heater if required. 
Heating is performed to the temperature limit plus ½°C and once that temperature is achieved heating will no re-occur 
until the temperature drops below the desired limit by ½°C or until the sample period has elapsed and the temperature 
is at or below the limit. 

 
SETTINGS MENU

 

All items on the LCD that flash are adjustable items, use the 

Up 

or

 Down

 buttons to modify the adjustable item. Press 

Enter

 to accept the adjustable value. 

To enter the SETTINGS MENU push either the up or down buttons and the following will be displayed; 
 

SETTINGS MENU 
1) MANUAL MODE 

 
All menu items are shown below, use the 

Up

 or 

Down

 buttons to scroll to different items in the menu; 

 

SETTINGS MENU 
1) MANUAL MODE 
2) TEMPERATURE 
3) HEAT DEMAND 