DONG SUNG SENSORS DQ Series Manual Download Page 1

QUICK FLOAT

LEVEL SWITCH

MANUAL

Revision No. 001 (2022)

DQ SERIES

Summary of Contents for DQ Series

Page 1: ...QUICK FLOAT LEVEL SWITCH MANUAL Revision No 001 2022 DQ SERIES ...

Page 2: ...CONTENTS 1 Introduction 2 Features 3 Operation Principle 4 Specification 5 Installation 6 Wire Connection 7 Dimensions 8 Contact Output 9 Maintenance ...

Page 3: ...le to refer immediately The specification of product mentioned in this manual may not be satisfied by the condition of your environment Please check and consider carefully before using The contents of this manual could be changed any time due to improvement of product It will be updated quarterly Please contact Dong Sung Sensors sales office department via email or phone for further questions ...

Page 4: ... Repair is done by the person who is not from Dong Sung 3 Improper parts are used and replaced 4 Damage is occurred by device or machine not from Dong Sung 5 Do not include fire earthquake tsunami lightning war radioactive pollution acts of Government compliance with law regulation and order 3 The warranty only covers the damage of products The secondary and third kind disasters are not covered by...

Page 5: ...uring shipment Thus please unpack carefully and visually check the product s exterior for damage Do not place in piles FRAGILE Please carry the sensor very carefully Sensor may not work properly if you drop or damage on it Do not remove the Sensor discretion This may cause damage and malfunction ...

Page 6: ... using buoyancy and magnetic force as multi wire signal transmission 2 Features Widely available with various liquid especially municipal water wastewater treatment plant and septic tank Simple installation Able to adjust on off position anytime Affordable price with accurate measurement DQ 3 Output the contact using mercury switch DQ 1 DQ 2 DQ 4 Output the contact using micro switch and steel bal...

Page 7: ...ing Ambient Temp control output Fuse Rating Material Mounting Dimensions DC 12V DC12 V DC 12V DQ 2U supply DQ 2U drain Base Plate ABS Cover ABS 49 w x 69 d x 61 h DQ 3U 4W H AL DQ 4U 5W L AL H AL AC 250V 5A 50 60Hz 88 5 w x 128 5 d x 66 h 0 60 C Power Supply AC 250V 100mA Wall Mount DQ 3 S W S W S W Mercury Micro 110V 1A 220V 3A Reed 220V 1A Mercury Micro 110V 1A 220V 3A Reed 220V 1A Mercury Micro...

Page 8: ...re tank During installation 1 Do not install the sensor near flow inlet 2 Make sure H AL spot do not go over overflow point 3 There must be enough room for movement of floats 4 It is recommended to connect to a single pipe to avoid malfunction caused by noise 5 Secure the switch to the wire at 150 mm from the top of the float 6 When assembling the Multi Wire Type assemble it in the order of L AL s...

Page 9: ...0 0 MADE IN KOREA DONG SUNG SENSORS CO Match the number of Controller and sensor To change DQ 3U s supply drain option use switching switch inside of Controller remove upper cover Check the connection state when you open close the Controller s cover Caution Make sure the connection between Level Controller and Sensor for proper use Sensor and Level Controller MUST be treated very carefully Check s...

Page 10: ...n Make sure the connection between Level Controller and Sensor for proper use Sensor and Level Controller MUST be treated very carefully Match the number of Controller and sensor To change DQ 4U s supply drain option use switching switch inside of Controller remove upper cover Check the connection state when you open close the Controller s cover ...

Page 11: ...7 Dimensions DQ 12F DQ 13F DQ 14F 1 DQ 22N DQ 23N DQ 24N ...

Page 12: ...7 Dimensions DQ 32F DQ 33F DQ 34F DQ 42F DQ 43F DQ 44F 1 ...

Page 13: ...LED 5 High Alarm LED 6 CONTROL LED 7 Low Alarm LED 8 TERMINAL STICKER 9 TERMINAL CONNECTOR 10 ASSEMBLY HOLE 66 H 128 5 D 88 5 W L E V E L C O N T R O L L E R m o d e l IN SIDE SUPPLY DRAIN 1 2 3 4 5 10 9 8 7 6 5 3 5 7 6 SUPPLY 1 2 3 4 5 HIGH LOW COM 1 Body 2 Cover 3 Model 4 5 6 Control LED 7 Terminal Sticker Terminal connector Assembly Hole 1 2 4 61 H 69 D 49 W MADE IN KOREA DONG SUNG SENSORS CO D...

Page 14: ...8 Contact Output DQ 2U DQ 3U DQ 4U H AL High Alram C Control L AL Low Alram ...

Page 15: ...not wire is disconnected somewhere 4 If motor or valve does not stop when Control LED is off check if wires are disconnected from control terminals If motor stops it is controller problem 5 If the power indicating LED lamp is off see if the fuse is OK 100mA 250V AC 6 For multi wire controllers disconnect the jumper from COM Then check controller output by shorting terminals one by one such as low ...

Reviews: