background image

Installation
and Operation Manual

IOM AD3029501

Revision 2

Modular MediaFilter

™ 

– Horizontal Series –

Ambient Collectors

Models HA-1A, HA-1B, HA-2A, and HA-2B

Throughout this manual
statements indicating
precautions necessary

 to avoid equipment failure

 are

referenced in a 

Note.

 Statements

indicating potential hazards that
could result in 

personal injury or

property damage

 are referenced

in a 

CAUTION!

 

box.

Illustrations in this manual are for
reference only, as actual product
may vary.

Installation,

Operation and

Service Information

This manual is property of the owner. Leave with the unit when set-up and
start-up are complete. Donaldson Company reserves the right to change design
and specifications without prior notice.

Summary of Contents for Torit MediaFilter Horizontal HA-1A

Page 1: ...ced in a Note Statements indicating potential hazards that could result in personal injury or property damage are referenced in a CAUTION box Illustrations in this manual are for reference only as act...

Page 2: ...ble materials are present consult with an installer of fire extinguishing systems familiar with these types of fire hazards and local fire codes for recommendations and installation of fire extinguish...

Page 3: ...__________________________________________________ Filter Type ____________________________________________________________________________ Accessories ________________________________________________...

Page 4: ...ndards The high efficiency filter system allows filtered air to be returned to the plant environment Designed to increase the versatility of the unit standard options include motor starter controls dr...

Page 5: ...t l o v 3 0 6 0 6 4 0 3 2 8 0 2 3 0 6 5 7 5 3 0 6 0 5 0 0 2 3 0 6 0 6 4 0 3 2 8 0 2 3 0 6 5 7 5 3 0 6 0 5 0 0 2 M F C l a n i m o n 0 0 0 3 o t 0 0 5 1 0 0 0 6 o t 0 0 0 3 r e w o p e s r o H r o t o...

Page 6: ...tage fiberglass vee bag filter The vee bag s open pleat design and precise bag spacing allows contaminant loading throughout the life of the filter As mist particles coalesce and form large droplets t...

Page 7: ...must complete installation and service of this equipment 4 All shipping materials including shipping covers must be removed from the unit prior to or during unit installation Note Failure to remove sh...

Page 8: ...for required voltage 4 If the unit is not furnished with a factory mounted disconnect an electric disconnect switch having adequate amp capacity shall be installed in accordance with Part IX Article 4...

Page 9: ...eaded rod to suspend unit 5 Place a 1 in flat washer on the threaded rod and thread a 1 13 lock nut a minimum of 1 1 2 in 6 Insert rod with washer and hex nut through the ceiling mount bracket from th...

Page 10: ...ardware in the clean and dirty air chamber 5 Plug the pressure ports on the back of the gauge using two 1 8 in NPT pipe plugs supplied Install two 1 8 in NPT male adapters supplied with the gauge into...

Page 11: ...clean air plenum drill location mounting bracket 6 32 x 1 4 in mounting screws support structure mounting surface Magnehelic gauge high pressure port low pressure port two 1 8 in NPT adapters plastic...

Page 12: ...fiO fiP d a p N O iN iO iP NP qN qO qP NQ O VR VS VT VU qN qO qP d g _ 1 Mount the control box in a convenient accessible location 2 Make the wiring connections to the fan motor according to the wiri...

Page 13: ...motor ON then OFF to check for proper rotation by referencing the rotation arrow located on the motor s mounting plate To reverse rotation single phase power supply Follow manufacturer s instructions...

Page 14: ...lter is used in machining processes generating large amounts of heat or in applications using straight oil as a lubricant or coolant Service Information Operational Checklist 1 Monitor overall perform...

Page 15: ...t allow particulate to fall into drain Vee Bag Filter Module Hopper 1 Access the hopper through the filter access doors 2 Clean hopper by scraping the particulate out Do not allow particulate to fall...

Page 16: ...Screen Cleaning 1 Place a suitable container under the screen clean out valve turn the collector OFF close the P trap valve then open the screen clean out valve 2 Allow fluid and particulate to drain...

Page 17: ...strainer body and reassemble taking care to seat the screen in the body and cap 4 Close the clean out valve 4 Refill the P trap with suitable fluid before restarting the collector Drain Collection Co...

Page 18: ...to shaft If it does not go on easily check shaft bushing and key sizes once again Tighten capscrews gradually and evenly with wrench similar to mounting an automobile wheel Rotate a quarter turn on ea...

Page 19: ...e c i v e d l o r t n o c r e m r o f s n a r t r o t o m m e l b o r p d e p p i r t y a l e r d a o l r e v O r o t o m n o w a r d p m a k c e h C d a o l r e v o t e s e R s p m a d e t a r e h t...

Page 20: ...d l a n o D e n i u n e g g n i s u e c a l p e r d n a e v o m e R g a B e e V e g a t S d n o c e S e e S s r e t l i f t n e m e c a l p e r 5 1 e g a P n o t n e m e c a l p e R r e t l i F r e t...

Page 21: ...Modular MediaFilter Horizontal Series Ambient Collectors 21 e t a D d e m r o f r e P e c i v r e S s e t o N Service Notes...

Page 22: ...Donaldson Company Inc 22 e t a D d e m r o f r e P e c i v r e S s e t o N Service Notes continued...

Page 23: ......

Page 24: ...ter elements to be free from defects in materials and workmanship for eighteen 18 months from date of shipment Donaldson does not warrant against damages due to corrosion abrasion normal wear and tear...