Installation, Operation and Maintenance manual
26
PowerCore
®
Dust Collectors - Series CPC
Filter pack replacement
Use safety and protective equipment when removing contaminants and filter
packs.
Dirty filter packs may be heavier than they appear.
Take care when removing filter packs for inspection.
Damaged filter packs must be replaced.
Do not drop filter packs.
Refer also to figure 12.
1. Turn off and isolate any air movement equipment associated with the process
(e.g. fan) and check clean air chamber is at atmospheric pressure.
2. Isolate controller and/or compressed air supply.
3. Open access door by releasing fasteners. Swing door fully open and engage
door locking mechanism.
4. Release filter pack retainer wing nuts and washers. Remove filter pack retainers.
5. Remove each filter pack by lifting straight up.
6. Place filter pack into a sealable bag and dispose of the filter pack properly.
If in doubt regarding the safe disposal of the used filter pack, consult your
local regulations.
A
B
Figure 11: Filter pack replacement (CPC-6F illustrated)
7. Clean surface around openings where filter packs are seated to ensure a good seal.
8. Insert new filter packs into place, ensuring seal (A) overlaps the six filter pack
locators (B).
9. Replace filter pack retainers, replace washers and tighten wing nuts so that each
filter pack seal is seated firmly.
10. Disengage access door locking mechanism, then close and fasten access door.