Installation, Operation and Maintenance manual
10
PowerCore
®
Dust Collectors - Series CPC
8. For collectors with dust container, locate position for dust container base panel,
drill through fixing brackets and secure with bolts. Adjust height to provide an
effective seal between dust container and sealer gear.
When the collector is fitted with an earthing post, an earthing connection
must be made between the base panel and the dust container, using the
earthing cable provided.
1
2
5
4
3
1
Collector
2
Dirty air plenum
(separate on PC-6, CPC-8 and CPC-12 only)
3
Hopper
4
Support
5
Dust container
Figure 3: PowerCore dust collector (model CPV-6F illustrated)