9
Donaldson Company, Inc.
Blower and Motor (Unpowered WSO 25-2
and 25-3)
The two types of blowers, Torit Backward Incline, TBI,
and Torit Radial Blade, TRB, are installed following the
same procedure. Both can be ordered for top mount.
1. The blower and motor are shipped assembled and
partial disassembly is required before installing.
2. Remove eight motor-mount bracket fasteners;
remove the motor, motor-mount bracket, and blower
wheel as an assembly as shown.
3. Turn housing over and apply sealant to the outside-
edge of the bolt pattern on the blower housing.
Mount the blower housing to the collector using the
inlet cone fasteners.
4. Apply sealant to the outside-edge of the bolt pattern
on the blower housing. Reinstall the motor, bracket,
and blower wheel assembly. Align the tab on the
blower housing with the slot in the motor-mount
bracket.
5. Rotate blower wheel after installation to ensure
proper clearance between the inlet cone and the
blower wheel.
Do not allow the fan wheel to
come loose from the motor as it
may cause severe injury or property damage.
To ensure proper attachment of the fan wheel:
Tighten all setscrews in fan wheel.*
Tighten all setscrews in bearings.*
Repeat after 8 hours of operation.
Repeat again after two weeks of operation.
Reference Wheel Setscrew Torque Table.
Wheel Setscrew Torque
Setscrew Size
Diameter
Carbon Steel Setscrew
Torque*
In.
Lb. - In.
Lb. - Ft.
1/4
75
6.2
5/16
144
12
3/8
252
21
7/16
396
33
1/2
600
50
5/8
1164
97
3/4
2016
168
7/8
3204
267
1
4800
400
*Stainless steel setscrews are not hardened and should not
be tightened to more than half of the values shown.
Summary of Contents for WSO 20
Page 1: ...IOM AK0300801 ENG Revision 3...
Page 5: ...200 Volt 380 Volt 3 Ph 50Hz 60 Hz...
Page 27: ......
Page 31: ......