Filter Installation
Dust Disposal
To avoid possible damage to the
fan motor maintain a seal below
the collector if servicing the dust storage
device while the fan is running.
1. Empty dust container(s) (drum or bin) as necessary
to minimize dust in the hopper.
2. If the optional 5-gallon pail pack or 55-gallon drum
attachment is used, empty when dust container is 2/3
full.
3. If optional slide gate is used, close gate before
servicing dust container.
Sharp edge of slide gate may
result in personal injury while
closing the slide gate. Keep hands clear when
operating the slide gate.
4. Check integrity of gasket under drum cover.
5. Replace or reinstall dust container and open gate (if
applicable).
Filter Installation
1. Check the gasket surface on the shaker panel and
clean as necessary.
2. Install new filter reusing the retaining ring and
tighten the four filter support knobs by hand.
3. Check the door gasket for condition and replace as
necessary.
4. Close bottom access door and secure latches.
Note: Slight bleed-through on new filters is normal
and will disappear as the filter seasons.