Torit PowerCore, CPV-1 to CPV-12
14
Compressed Air Components
Do not set compressed-air
pressure above 100-psig.
Component damage can occur.
1. Periodically check the compressed air components
and replace compressed-air filter.
2. Drain moisture following the manufacturer’s
instructions.
3. With the compressed-air supply ON, check the
cleaning valves, solenoid valves, and tubing for
leaks. Replace as necessary.
NOTICE
Electrical Connection (CPV-1 Only)
Electrical work must be
performed by a qualified
electrician and comply with all applicable
national and local codes.
Turn power off and lock out electrical
power sources before performing service or
maintenance work.
Do not install in classified hazardous
atmospheres without an enclosure rated for
the application.
1. Using the wiring diagram supplied, wire the
customer-supplied disconnect switch and fan
starter. Make the connections to the fan motor.
Use appropriate wire gauge for rated amp load as
specified by local codes.
2. Turn the fan motor On then OFF to check for proper
rotation by referencing the rotation arrow located on
the motor's mounting plate.
Do not look into fan outlet to
determine rotation. View the fan
rotation from the back of the motor.
Check that the exhaust plenum is free of tools
or debris before checking blower/fan rotation.
Stand clear of exhaust to avoid personal injury.
To reverse rotation, three-phase power supply: Turn
electrical power OFF at source and switch any two
leads on the output-side of the fan motor starter.
Do not interchange a power lead
with the ground wire. Severe
personal injury or equipment damage may
result.