Galvanized Hard Sided Booth Assembly
Note: Use M8 x 45 mm bolts to fasten the side rail
channels.
Use M8 x 35 mm bolts to fasten the top support
channels.
Use M8 x 20 mm bolts for the remainder of the
assembly.
1. Fasten the module side panel angles to the right and
left side of the assembled power modules.
2. Fasten the top panel angle to the top front of each
power module.
3. Assemble two booth panels and a side panel angle to
form a wall unit.
4. Attach wall to the outside of the power module side
angle.
Note: The stiffener side is the external wall and the
side-rail channel is the inside.
5. Fasten the side-rail channels to the wall using
M8 x 45 mm long bolts, flat washers, and hex nuts.
6. Bolt the gussets to the right and left support legs
and fasten the support legs to the edge of the
corresponding walls.
7. Bolt the top support channel to the gussets.
Note: The DWS-2 requires one top support channel.
DWS-3 and DWS-4 require two top support
channels. When assembling the DWS-3 or
DWS-4, bolt the two top support channels and
the top support tie in together and then bolt to
the gussets.
Roof panels are not intended
as platforms. Personnel should
use ladders or other appropriate equipment to
avoid risk of personal injury and/or property
damage.
8. Install and bolt the booth roof panels in place.
Note: Temporary roof support during assembly is
not required. The top panel angles and the top
support channels support the roof panels.
9. Place the light fixture on the clear panel between the
stiffener angles on the booth roof.
Light Fixture for Hard Sided Booths
1. Attach the light mounting angles to the booth roof
panels using M8 x 20 mm bolts, flat washers, and hex
nuts.
2. Mount the light fixture to the mounting angles
using M8 x 20 mm bolts, flat washers, and hex nuts
supplied.
3. Install customer-supplied fluorescent bulbs.
4. See Electrical Installation for wiring connections.
5. Diaphragm valves have an external solenoid
enclosure mounted inside the clean air plenum
on the pressure manifold. Wire each solenoid by
loosening the solenoid enclosure cover fastening
screws. Pull the cover from the solenoid enclosure.
Wire solenoids through access points in rear
of cabinet and enclosure by referencing wiring
diagram.