Downflo Workstation, DWST 4-1 to 6-4
A18
Light Fixture
Electrical work must be performed by a qualified electrician and comply with all applicable national and local codes.
Turn power off and lock out electrical power sources before performing service or maintenance work.
Do not install in classified hazardous atmospheres without an enclosure rated for the application.
Wire the fixture following the wiring diagram included with the fixture.
Afterfilters
1. Place 1/4-in diameter rope-type sealant to the top flange
of the power module.
2. Position the afterfilter plenum on the power module with
the vertically mounted afterfilter facing over the booth.
3. Fasten using M8 x 20 mm bolts and flat washers.
4. Install the afterfilters in the afterfilter frame.
5. Install HEPA filters with the filter gasket toward the inside
of the frame.
6. Install ASHRAE filters with the airflow arrow pointing to the
outside.
7. Position the clamping straps and tighten the wing screws
securely.
Optional AfterFilter Installation
Delta P Control
For complete information, see the most current version of the Delta P Installation, Operation and Maintenance manual.
Delta P Plus Control
For complete information, see the most current version of the Delta P Installation, Operation and Maintenance manual.