![Donaldson Torit DFE 2-4 Installation And Operation Manual Download Page 35](http://html.mh-extra.com/html/donaldson-torit/dfe-2-4/dfe-2-4_installation-and-operation-manual_2520663035.webp)
Downflo Evolution, DFE 2-8 to 5-80
32
Extended Dirty-Air Plenum
The extended dirty-air plenum is used in applications
requiring an air management module or when a single
inlet serves multiple modules.
The extended dirty-air plenum is supplied with standard
service access panels on the sides and top of the
plenum.
The top access panel is available with and without an
explosion vent.
Extended Dirty-Air Plenum
Air Management Module
Air Management Module
The air management module is used in applications
involving heavy grain loading, large or abrasive particles
in the airstream, or in applications when a collector with
a single inlet serves multiple modules. It is equipped with
a louvered panel near the bottom, which prevents re-
entrainment of the dust that falls through to the hopper.
This module does not contain filters, and is available for
use with an extended dirty-air plenum only.
Air management modules are supplied with a standard
36 x 24-in and 36 x 16-in covered opening on front of the
collector.
Summary of Contents for DFE 2-4
Page 42: ...A 1 Donaldson Company Inc Appendix A Clean Change Bag In Bag Out Filter and Liner System...
Page 56: ...B 2 Donaldson Company Inc Service Notes Date Service Performed Notes...
Page 57: ...Downflo Evolution DFE 2 8 to 5 80 B 3 Date Service Performed Notes...
Page 58: ...B 4 Donaldson Company Inc Date Service Performed Notes Service Notes...