A table is then displayed with the default parameters configured for each programme.
5. ALARMS AND WARNINGS
The open door and open filter alarms lead to the pausing of the current programme. When the
conditions triggering the alarm disappear, the drying cycle can be restarted as soon as the alarm
is closed. The other alarms stop the programme and a warning alarm is heard. This warning is
stopped by pressing SELECT or by removing the reason for the alarm.
The following table lists the alarms and their possible causes.
Alarm Meaning
Possible solutions
AL-1
Door open
* Close the door.
AL-2
Filter cover open
* Close the filter cover.
AL-3
No flame
* Check gas supply cock open.
* Check that the pressure is correct. See 3.4.
AL-4
Pressure drop failure
or insufficient air flow
* Check that the outlet conduit is free, check that it is not too
long.
* Check that the filter is fluff-free.
* Check that the fan's turbine is fluff-free.
AL-5
Motor - fan overload
* Check that the outlet conduit is correctly connected, and
does not have a free outlet.
AL-6
Over temperature
* Check that the air flow is correct.
* Check gas pressure is correct.
Note: the safety thermostat has to be rearmed.
AL-7
Dirty filter
* Clean the filter.
* Clean filter more regularly, do not reach this point.
This alarm is never displayed in self-service models
AL-9
Probe Alarm
* Problem with the temperature and/or humidity probes.
Contact your Technical Assistance Service.
If any of the previous alarms were to persist, consult your Technical Assistance Service. Always
use the machine's serial number for your queries.
PROGRAM
RECOMMENDED
USE
DRYING
ROTATION
TIME
Min
ºC
%H.R.
1
TOWELS
30
80
25
70
2
COTTON 1
35
75
25
70
3
COTTON 2
40
65
30
70
4
SYNTHETICS
20
60
30
70
5
DELICATES
25
45
30
70
6
INTENSIVE 1
20
75
30
70
7
INTENSIVE 2
30
75
30
70
8
EXTRA 1
15
90
20
30
9
EXTRA 2
20
90
15
30