background image

INSTALLATION MANUAL

EN

- Use 24Vdc constant voltage power suppliers only with power 
exceeding the total load by at least 10%. 

X-SIGN TDM

 can guide a 

maximum load of 50W @ 24Vdc, thus a maximum 

5

 

X-SIGN

.

OPERATION:
X-SIGN TDM

 and 

X-SIGN 4F TDM

 refer to configurations of the 

equipment integrating a dimmable electronic switch (D) which enables 
switching on, switching off and adjusting light intensity. As indicated in 
the INSTALLATION section, these can be installed alone or combined 
with 

X-SIGN

 or with 

X-SIGN 4F

 (switch-less equipment) to enable 

switching on, switching off and adjusting all equipment simultaneously.
The apparatus can be easily switched on and off by touching the switch 
(D).
Extended touching of the switch enables adjusting the light intensity 
increasing or reducing it. A brief blinking of the equipment indicates 
that maximum brightness has been reached. 
The brightness level will be memorised until the next adjustment.

WARNING

- The LED module and the power supply cable of this equipment cannot 
be replaced,
thus, the entire equipment must be replaced in case of failure.

WARRANTY:

The warranty on the device is valid only if powered by a power supply 
provided by DOMUS Line. The warranty’s general terms and conditions 
for this device are available at 

www.domusline.com

WARNING:

Safety is guaranteed if these instructions are followed and therefore 
they must be kept. Installation may require the involvement of qualified 
personnel. Before proceeding with installation of the device ensure that 
the environmental conditions are in compliance with and suitable for 
the product characteristics. Before any operation on the device 
disconnect mains power.

INTRODUCTION: 
X-SIGN TDM

 is a light equipped with an electronic switch (D) wired in 

MASTER version. It can be installed alone or combined with 

X-SIGN 

SLAVE

 (without switch) to enable switching on, switching off and 

simultaneous adjustment of all equipment (max. 6 in all).

INSTALLATION:

- Use the drilling template (E) for the correct positioning of the 
equipment 
- Position the drilling template at the rear part of the hanging elements 
and drill the indicated holes (

X-SIGN

: 4 ø3mm holes + 1 ø9mm hole for 

the exit of the cable or 

X-SIGN 4F 

: 5 ø3mm holes + 1 ø9mm hole for the 

exit of the cable) see figures 1 and 2. 
- Fix the bracket (A) using the screws (B) in the packaging. 
- Thus couple the light (B) by matching the hooks present in the bracket 
with the relative holes on the light and thus pressure-couple it.
- Electrically connect the lights to the power supply complying with the 
wiring diagram (fig. 3,4,5,6) using the extensions (C) provided in the 
packaging if necessary.
- Connect the power supply plug (F) to an alternating current socket 
(230V 50/60Hz).

Summary of Contents for 8027934272183

Page 1: ...avoro 1 33080 PORCIA _ PN _ Italy phone fax e mail website 0039 0434 595911 0039 0434 923345 info domusline com www domusline com MANUALE DI INSTALLAZIONE E USO INSTALLATION MANUAL INSTALLATIONSHANDBUCH MANUEL D INSTALLATION MANUAL DE INSTALACIÓN IT EN DE FR ES Ref 3481100_r0 ...

Page 2: ...f the product implies the application of the administrative sanctions envisaged by the prevailing regulation Die Leuchte muss getrennt vom Hausmüll entsorgt und entsprechend der geltenden Richtlinien an den vorgesehenen Sammelstellen abgegeben werden Die angemessene getrennte Sammlung trägt dazu bei eventuelle negative Auswirkungen auf die Umwelt und die Gesundheit zu vermeiden und die Wiederverwe...

Page 3: ...X SIGN X SIGN4F ...

Page 4: ...Fig 1 Fig 2 A N 4 x Ø3mm N 1 x Ø9mm N 5 x Ø3mm N 1 x Ø9mm drilling template drilling template drilling template drilling template E E back side back side X SIGN X SIGN4F B D D A B E E E E ...

Page 5: ...r Master switch Converter X SIGN TDM with TouchDimmer Master switch X SIGN slave without TD X SIGN slave without TD C C C C C F F F Fig 3 Fig 4 Fig 5 Fig 6 D D MAX 5x Converter X SIGN slave without TD X SIGN slave without TD C C F Switch ON OFF X SIGN TDM with TouchDimmer Master switch D Switch ...

Page 6: ...ali di garanzia di questo apparecchio sono disponibili sul sito www domusline com AVVERTENZA La sicurezza è garantita se si seguono queste istruzioni e pertanto è necessario conservarle L installazione può richiedere il coinvolgimento di personale qualificato Prima di procedere all installazione dell apparecchio assicurarsi che le condizioni ambientali siano conformi e idonee alle caratteristiche ...

Page 7: ...ce are available at www domusline com WARNING Safety is guaranteed if these instructions are followed and therefore they must be kept Installation may require the involvement of qualified personnel Before proceeding with installation of the device ensure that the environmental conditions are in compliance with and suitable for the product characteristics Before any operation on the device disconne...

Page 8: ...einem Netzteil der Firma DOMUS Line gespeist wird Die allgemeinen Garantiebedingungen dieser Leuchte stehen auf www domusline com zur Verfügung HINWEIS Die Sicherheit wird nur gewährleistet wenn diese Anweisungen befolgt werden Sie sind daher aufzubewahren Für die Montage kann qualifiziertes Personal erforderlich sein Vor der Montageder Leuchte sicherstellen dass die Umgebungsbedingungen konform u...

Page 9: ...ig 3 4 5 6 en utilisant si nécessaire les rallonges C présentes dans l emballage Brancher la fiche F de l alimentation sur une prise secteur 230 V 50 60 Hz Utilisez uniquement des alimentations à tension constante 24 Vdc d une puissance 10 supérieure à la charge totale X SIGNE TDM peut supporter une charge maximale de 50 W en 24Vcc donc un maximum de 5 X SIGN FONCTIONNEMENT X SIGN TDM et X SIGN 4F...

Page 10: ...e este aparato están a disposición en www domusline com ATENCION La seguridad está garantizada si se siguen éstas instrucciones La instalación puede requerir la participación de personal cualificado Antes de proceder con la instalación del dispositivo asegúrese de que las condiciones ambientales son las adecuadas para el producto Antes de cualquier operación hay que comprobar que la red eléctrica ...

Reviews: