PSS5000/TEMA/803046/14
123 of 155
PSS 5000 – Technical Manual
9 W & M (Menu W)
5.
Use the
and
buttons to toggle between
ON
and
OFF
.
When the RTC ERROR value is
ON
, this simulates that the real time clock
has an error and the PSS 5000 must react accordingly.
6.
Return the checking device setting to
OFF
before you leave the PSS 5000.
Failure to do this will result in the PSS 5000 not operating correctly.
9.7.5
Trans Memory (Menu W.7.5)
To activate trans
memory errors with web
service pages
The procedure used here is the same procedure as is used to check all the de-
vices, see
‘To activate checking devices with web service pages’ on page 119
.
To activate checking
Transaction Memory with
local service panel
This procedure describes how to activate the built-in checking device that
makes sure that the Transaction Memory checking facility is operating cor-
rectly.
1.
Press
to move to the
LAM VERSION W.1
menu.
2.
Press , , , , ,
to
move
to
the
CHECKING DEVICES W.7
menu.
3.
Press , , , ,
to
move
to
the
TRANS MEMORY ERR W.7.5
menu.
4.
Press
to move to the
TRANS MEMORY ERR
menu.
5.
Use the
and
buttons to toggle between
ON
and
OFF
.
When the TRANS MEMORY value is
ON
, this simulates that the memory
has an error and the PSS 5000 must react accordingly.
6.
Return the checking device setting to
OFF
before you leave the PSS 5000.
Failure to do this will result in the PSS 5000 not operating correctly.